Back to search

University of Patras

Ενίσχυση υφισταμένων κτιρίων οπλισμένου σκυροδέματος με ανοικτούς ισόγειους ορόφους (pilotis) για βελτιωμένη αντισεισμική συμπεριφορά

Abstract

dc:description

The present doctoral thesis deals with the problem of optimum partial strengthening of existing reinforced concrete (RC) buildings with open ground stories (Pilotis) designed and constructed before 1984, according to the old Greek Codes. The study focuses on retrofitting solutions restricted to the ground level so that the total cost is kept to a minimum and the buildings remain in use during the interventions. The current state of knowledge on complete strengthening of existing buildings at predefined levels of seismic performances in Greece and worldwide is satisfactory. The problem however of partial retrofitting, where strengthening of one story (i.e. of only the open ground story) affects the response of one or more adjacent stories, has not been adequately addressed so far, reflecting the motivation and the originality of this research effort. The most significant motivation, however, is the practical importance of this subject, because: (a) old RC buildings with open ground stories represent the most vulnerable class of existing buildings in Greece, and (b) partial retrofitting is the only feasible solution for large scale interventions through State introduced incentives. For dealing with this problem an extensive numerical investigation of the seismic performance of Pilotis type buildings partially strengthened at their open ground story is conducted, using nonlinear analysis methods. Optimum retrofitting solutions, i.e. the required amount of strengthening which results in the maximum reduction of the buildings’ vulnerability, without shifting the problem to any of the overlying non-retrofitted stories, are determined via a trial and error procedure. Buildings are strengthened using: (a) conventional X- or Λ- diagonal steel braces, (b) RC jacketing of the ground story columns, and (c) steel dissipative systems such as buckling restrained braces or ductile shear links in some of the examined cases. The flexibility of the soil as well as the foundation’s geometry and their effects on the seismic response before and after strengthening are also briefly examined. Eurocode 8 – Part 3 is applied for the assessment of the seismic performance of the original and the partially strengthened buildings. Based on the nonlinear analyses results of the detailed mathematical models, simplified equations are proposed for a preliminary estimation of the optimum retrofitting solutions, in terms of global story strength and stiffness indices. Finally, a simple MDOF stick model with one element per story is proposed and applied in the analysis of the problem. The proposed simplified model appears suitable in substituting the corresponding complex mathematical models of the buildings under consideration and can be used for a fast and accurate assessment/design of many partial retrofitting alternatives. Results of a parametric study are presented. Retrofitting cost estimates are also given for some of the typical examined cases. This research effort shows that partial strengthening by intervening only in the open ground story of existing old designed Pilotis buildings turns out to be beneficial in preventing from soft or weak ground story collapse mechanisms. Since it can be carried out externally without interrupting the buildings’ operations, without causing any additional retrofitting works or transferring of the occupants to temporary accommodations, it is the only realistic way towards a reduction in the seismic hazard of our country, through large scale applications.

Degree

thesis:*
Grantor dc:publisher
University of Patras
Year dc:date
2014

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Antonopoulos, Themistocles
  • Αντωνόπουλος, Θεμιστοκλής

Subjects

dc:subject × 22

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/36846

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Antonopoulos, Themistocles; Αντωνόπουλος, Θεμιστοκλής. Ενίσχυση υφισταμένων κτιρίων οπλισμένου σκυροδέματος με ανοικτούς ισόγειους ορόφους (pilotis) για βελτιωμένη αντισεισμική συμπεριφορά. University of Patras, 2014. http://hdl.handle.net/10442/hedi/36846