University of Ioannina
Ανάπτυξη, βελτιστοποίηση και επικύρωση υγρής-υγρής μικροεκχύλισης και μεθοδολογίας αέριας χρωματογραφίας συζευγμένης με φασματομετρία μάζας για τον προσδιορισμό πολυκυκλικών αρωματικών υδρογονανθράκων με τη χρήση χημειομετρικών μεθόδων σε υδατικά δείγματα: εκτίμηση οικοτοξικολογικού κινδύνου για την λεκάνη απορροής του ποταμού Άραχθου
Abstract
dc:descriptionThe aim of the study is first to exploit the analytical utility of dispersive suspended microextraction for the determination of PAHs in natural water samples, for the first time, followed by gas chromatography–mass spectrometry(GC/MS). The second is to evaluate and optimize the method with the aid of response surface methodology and experimental design. And finally the third is to calculate the potential ecological risk of the PAH residues in Nestos River basin.For the DSME procedure, 4.3 mL of aqueous sample was placed in a 10-mL crimp-top glass vial sealed with an open centered aluminum cap and with a PTFE-gray butyl septum. A 93 μL aliquot of toluene, taken with single channel pipette, was added as the extraction solvent to the surface of the aqueous sample. A magnetic micro stirring bar was placed at the bottom of the vial. The sample vial was placed on a magnetic stirrer to stir the sample.The DSME procedure first involved an extraction step, followed by a restoration step. In particular, the stirring speed was set at1500 rpm (extraction speed) for 104 s (extraction time) and then was reduced to 800 rpm (restoration speed). In the extraction step, a cloudy solution was formed, and the analytes in the water sample were extracted into fine toluene droplets. When the stirring speed was adjusted to 800 rpm, the restoration step began. At this stirring speed, a gentle vortex was formed and the toluene droplets began to coalesce. After 10 min (restoration time), the toluene had separated from the aqueous phase, and an organic droplet was formed in the bottom center of the vortex. Finally, after the restoration step, 1.5 μL of the organic phase was collected with a10 μL micro syringe with a small hub removable needle and injected into the GC–MS for further analysis.The proposed method was applied to real water sample analysis. Different types of water samples obtained from eight sample stations were used, including river and lagoon sources. Among the target analytes, seven PAHs were detected in three of a total of eight sample stations. Specifically, six PAHs were detected in one sample station, while five sample stations were totally free from PAH residues. To conclude, in the present study, for the first time, DSME coupled with GC–MS was evaluated for the simultaneous determination of PAH residues in real water samples. This simple, rapid and inexpensive extraction method fulfilled analytical validation criteria. The sensitivity and linear dynamic range were relevant to environmental water analysis, and accurate measurement of the compounds of interest in surface waters was achieved.
Degree
thesis:*- Grantor dc:publisher
- University of Ioannina
- Year dc:date
- 2016
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Petridis, Nikolaos
- Πετρίδης, Νικόλαος
Subjects
dc:subject × 18- Υγρή-υγρή μικροεκχύλιση αιωρούμενης σταγόνας σε διασπορά
- Πολυκυκλικοί αρωματικοί υδρογονάνθρακες
- Πειραματικός σχεδιασμός
- Μεθοδολογία επιφάνειας απόκρισης
- Φυσικά νερά
- Οικοτοξικολογικός κίνδυνος
- Dispersive suspended microextraction
- Polycyclic aromatic hydrocarbons
- Experimental design
- Response surface methodology
- Natural waters
- Ecological risk assement
- Φυσικές Επιστήμες
- Χημεία
- Γεωεπιστήμες και Επιστήμες Περιβάλλοντος
- Natural Sciences
- Chemical Sciences
- Earth and Related Environmental Sciences
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/37023