University of Patras
Έλεγχος του βαθμού ενδοθηλιοποίησης των στεφανιαίων αρτηριών με τη μέθοδο της οπτικής συνεκτικής τομογραφίας σε ασθενείς με ενδοστεφανιαίες προθέσεις που εκλύουν πακλιταξέλη έξι μήνες μετά την αρχική τους εμφύτευση στα πλαίσια οξέος στεφανιαίου συνδρόμου
Abstract
dc:descriptionBackground: The incomplete neoendothelialization and malapposition of drug-eluting stent struts has been correlated with an increased incidence of late and very late thrombosis in a number of studies. Although there is plenty of available data after the implantation of sirolimus-eluting stents, the evidence concerning the degree of neoendothelial coverage and strut apposition for paclitaxel-eluting stents is, before the publication of this study, scarce. This is particularly true for stents deployed in the context of an acute coronary syndrome, which has been linked by numerous studies to an increased incidence of incomplete stent apposition. Optical coherence tomography represents an excellent tool for the detailed and accurate detection of the coverage and apposition of every single strut of implanted stents, with an axial spacial resolution of as minute as 10 μm. Objective: The prospective optical coherence tomography study of strut apposition and neointimal hyperplasia thickness (NIH) of a paclitaxel-eluting stent (PES), (Infinium, Sahajanand Medical Technologies Pvt Ltd.) 6 months after its implantation in the context of an acute coronary syndrome. To the best of our knowledge, this is the first worldwide published prospective study of coverage and apposition of this specific type of PES in a cohort of patients exclusively after an acute coronary syndrome.Results: At 6 months no patient demonstrated angiographic restenosis. 3180 struts from 20 stents were analysed, and 91.3% were covered with neointima (NIH 204.8 ± 159.5 μm). Standard statistics and least squares estimates (LSE) derived from a hierarchical ANOVA model to take into account clustering effects are presented. The rate of uncovered struts was 8.6%, LSE 7.39 (95% CI 3.05–11.73), of malapposed struts 2.2%, LSE 1.76 (95% CI 0.05–3.58), and of protruding struts 2.9%, LSE 2.8 (95% CI 1.35–4.65). The proportion of uncovered malapposed struts was significantly higher compared to uncovered embedded struts (55.7% vs. 6.8%, respectively, p < 0.01). In total, 5 (25%) PES were fully covered by neointima. No intracoronary thrombus or clinical events were detected.Conclusions: Six months after implantation of a specific PES in patients with ACS, most of the stents were only partially covered with neointima, especially at sites of strut malapposition or protrusion. These findings emphasize the need for optimal stent apposition during implantation and for prolonged dual antiplatelet therapy.
Degree
thesis:*- Grantor dc:publisher
- University of Patras
- Year dc:date
- 2016
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Nikokiris, Georgios
- Νοικοκύρης, Γεώργιος
Subjects
dc:subject × 10Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/37055