Έλεγχος αποτελεσματικότητας, με ενόργανες αναλυτικές τεχνικές, συστήματος επεξεργασίας υγρών αποβλήτων με χρήση μεμβρανών: τεχνικές βελτίωσης λειτουργικής απόδοσης συστημάτων MBR
Abstract
dc:descriptionReuse of treated wastewater is basic need of modern societies supported from relatively legislative frames. Wastewater treatment in MBR installations has been proved important in both small or full scale plants. The big problem of these installations is clogging because of membrane fouling, which needs high intensive air flow for the cleaning of membranes and consequently requires high energy consumption. Internationally the objective of all scientific community is to considerably decrease the consumption of air in these systems. In the present thesis the operation of MBR pilot unit is presented with use of novel synthetic wastewater (simulation of municipal wastewater). In this pilot unit, research was conducted with various mechanical, physical and chemical methods of membrane cleaning in the effort to face the problem of clogging and control of functionalism of membranes with the lower energy cost. With regard to the effectiveness of the MBR system was in conclusion confirmed the exceptional performance in removal of organic load concerning the inflow concentration in terms of COD (>96%) as well as in terms of BOD5 (97%) in all the examined retention times and sludge age (10-60 days) as well as in increased organic loads (COD inflow 675-705 mg/lt). Moreover, the removal efficiency of total nitrogen was relatively good as it presented important reduction of load in terms of total nitrogen (~50%), compared to the ww inflow concentration, independent from the temperature fluctuations and the changes of MLSS concentration of the sludge. Also the reduction of total phosphorus was very high i.e. between 80-90% compared to the, ww inflow in the MBR. Finally the removal of microbial load was exceptional as it was expected, after bacterial indicators of pollution and pathogenic bacteria were almost not detected in the permeate.Various types of mechanical, physical and chemical methods of cleaning that were applied extensively in the present thesis gave improved functional characteristics of MBR systems. The two major parameters examined for all applied methods was that of the transmembrane pressure (TMP) and the filtration flux, i.e. the permeate flow (flux) of every system. Specifically, for the experimental circle with vibrating ball improvement of TMP in the range of 4,7-5,5% and increase of flow between 2,5-3,1% for the near membranes was observed, concerning the values before the application of vibration. For the experimental circles with ultrasounds improvement of TMP in the range of 0,3-1,9% and increase of flow of filtrate at 1,3-7,2% was observed, while simultaneously a decrement of MLSS in the range of 0,7-9,2% concerning the values before the application of ultrasounds was observed, where the highest values correspond in bigger periods of application of ultrasounds. At the application of high frequency vibration with pneumatic vibrators, improvement of TMP and Flux for the all experimental circles was recorded. Concretely in the 1st experimental circle of application of vibration HFPV in a module of three hollow fiber membranes (SINOMA) with the implementation of HFPV scheme reduction of TMP in the range of 4-28,3% and increase of flow of permeate at 10,6-17,3% was recorded, depending on the applied form of vibration recovering almost the initial values of flow of permeate (5 - 6 l/m2h) and reducing considerably the values of TMP (roughly 75mbar from 200 mbar). The system maintained the above high performance of functional characteristics for a period of almost three days where vibration HFPV was periodically applied, initially every 2 hours, then every 4 hours and finally every 6 hours. After the interruption of vibration schemes, the functional characteristics of provision of membranes followed similar profiles with the one that they had at the beginning of experiment. In the 2nd experimental circle the effect of three different forms HFPV of vibration in parallel operation of four membranes of concave fibers (KHONG) was examined. In each set of examined membranes similar results were recorded. In first examined membranes (A1 and A4) two different forms of vibration (VT1 and VT5) were applied with the same vibrator while in the second ones (A3 and A6) a third form of vibration was applied (VT2) with another, more powerful vibrator and the different effects were observed. Thus for the first membranes medium reduction of TMP at 27% and increase of flow of filtrate at 25% for the first form of vibration were recorded (VT1) while proportionally reduction of TMP at 42% and increase of flow of filtrate at 100% for the second form of vibration were recorded (VT5). At the simultaneously functioning membranes (A3 and A6) medium reduction of TMP at 65% and increase of flow of permeate at 60% for the vibration scheme was recorded (VT2) which began being applied the same day. In the 3rd experimental circle in flat sheet membranes before the application of vibrations, a permanent cake layer of sludge was stucked between the membranes. The values of TMP were almost 100 mbar and flow was almost 3,5 l/m2h. Under these conditions, vibration HFPV with progressive increase of vibration schemes force was applied. Scheme VT1 that was applied two times allowed a provisional small medium improvement of TMP at 9,5% as well as a increase in the flow of permeate at 20%. Following, another vibrating scheme was implemented, VT2 vibration, where medium reduction of TMP prices at 11% was recorded while the medium flow of permeate after the third application of vibration was increased at 50% and therefore the breaking to pieces of permanent layer of sludge fouling that had taken shape between the membranes was observed. The further application of method HFPV with the same scheme of vibration that was applied after the removal of sludge layer, showed that it can ensure constant behavior of functional characteristics, preventing the increase of pressure and the reduction of flow of membrane filtration. The above experiments were carried out with low membrane cleaning air supply and this has particular energy value because in H.F membranes the energy profit exceeded the 30% of conventional method while in membranes F.S this touched upon the 85%. In the experimental circle of membrane backwash, improvement of TMP values before and after the backwash implementation was presented in percentages that varies from 16,7-28% depending on the temperature of the backwash water, the type of membrane, the time of backwash implementation and the initial situation of membrane, while the corresponding rates of flux improvement oscillated from 12% to 25%. Finally, in the experimental circle that the method of interrupted operation was examined, the TMP and flux presented improvement concerning their values before the process in percentages which oscillated from 1,5-4% depending on the time of interruption and the type of membrane. The experimental results of this study indicate that MBR modules have functionally improved, restricting membrane clogging. The methods that were used can be considered as innovated and applicable in real scale plants, ensuring energy and operational profit.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2016
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Chatzikonstantinou, Konstantinos
- Χατζηκωνσταντίνου, Κωνσταντίνος
Subjects
dc:subject × 5Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/37135