Back to search

Aristotle University Of Thessaloniki (AUTH)

Ανάπτυξη αυτόματων μικρο-τεχνικών προκατεργασίας δείγματος για τον προσδιορισμό μολύβδου και υδραργύρου με συνδυασμένες αναλυτικές τεχνικές

Abstract

dc:description

The experimental data lead to the following:1) A simple and fast preconcentration/separation dispersive liquid–liquid micro extraction method for metal determination based on the use of extraction solvent with lower density than water has been developed. For this purpose a novel micro-volume introduction system was developed enabling the on-line injection of the organic solvent into flame atomic absorption spectrometry. 2) A novel automatic on-line liquid phase micro-extraction method based on drop-in-plug sequential injection lab-at-valve platform was proposed for metal preconcentration and determination. A flow-through micro-extraction chamber mounted at the selection valve was adopted without the need of sophisticated lab-on-valve components. Coupled to flame atomic absorption spectrometry, the potential of this lab-at-valve scheme is demonstrated for trace lead determination in environmental and biological water samples. 3) A novel and versatile automatic sequential injection countercurrent liquid–liquid microextraction system coupled with atomic absorption spectrometry is presented for metal determination. The extraction procedure was based on the countercurrent flow of aqueous and organic phases which takes place into a newly designed lab made microextraction chamber. A noteworthy feature of the extraction chamber is that it can be utilized for organic solvents heavier or lighter than water. 4) A novel fully automated headspace single drop microextraction system based on a programmable lab-insyringe platform hyphenated to electrothermal atomic absorption spectrometry for in situ vapor generation assays, was developed. Mixing of precise metered volumes of sample and stannous chloride solutions along with generation of mercury vapor were accomplished inside the microsyringe under reduced pressure environment in a closed manner excluding the possibility of analyte losses. The released of mercury vapor was trapped on the surface of aqueous microdrop consisting of finely dispersed palladium via amalgamation process.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2016

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Mitani, Constantina
  • Μητάνη, Κωνσταντίνα

Subjects

dc:subject × 12

Rights

dc:rights
Statement dc:rights
  • BY
Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/37354

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Mitani, Constantina; Μητάνη, Κωνσταντίνα. Ανάπτυξη αυτόματων μικρο-τεχνικών προκατεργασίας δείγματος για τον προσδιορισμό μολύβδου και υδραργύρου με συνδυασμένες αναλυτικές τεχνικές. Aristotle University Of Thessaloniki (AUTH), 2016. http://hdl.handle.net/10442/hedi/37354