Back to search

University of Patras

Συμβολή στο σχεδιασμό ηλεκτρονικών μετατροπέων ισχύος για διασυνδεδεμένα με το δίκτυο χαμηλής τάσης φωτοβολταϊκά συστήματα

Abstract

dc:description

The present Ph.D thesis deals with distributed, building-integrated, 1–20kW Photovoltaic (PV) Systems that are connected to the low voltage distribution network. More specifically, the focus of this research lies on the investigation of control methodology and inverter behavior, through which PV arrays are connected to the low voltage distribution network, following the emergence of fault in one of the connection points between the PV systems and the network. The main purpose of this thesis is to contribute to the field of dispersed PV Systems’ development by aiming at the achievement of building-integrated PV systems’ high level penetration to the low voltage distribution network. Such an achievement is integrally connected to the appropriate design and control of PV inverters, so that, in case of a disturbance, they may respond in a supplementary fashion, consonant to the demands of the latest grid codes. The successful completion of this research was dependent on the accomplishment of the following stages and goals:Bibliographical research pertaining to the latest grid codes, in particular with reference to Fault Ride Through Capability (FRTC) of dispersed generation units in case of network fault.Investigation of the dispersed, connected to a low voltage distribution network, PV Systems’ conduct in case of permanent fault, following the implementation of a control methodology that will result in the systems’ functioning as conventional synchronous generators; furthermore, the systems’ design parameters’ impact is a seminal factor that also needs to be taken into consideration. Exploration of the capability of achieving a high level penetration of PV low voltage units into a radial distribution network, through their optimized design.Formulation of a control methodology referring to low voltage distribution network PV systems that will enable the unobstructed operation of the system when at steady state, while at the same time contributing to the FRTC demand when in faulty state. In accordance with the goals and research procedures outlined above, this dissertation first presents a bibliographical review of the heretofore implemented rules and regulations related to dispersed units, predominantly grid-connected low voltage PV Systems, in case of network fault. Next, this review looks into network codes that have been developed in the past decade, which introduce the demand for Fault Ride Through Capability (FRTC) into high power, distributed generation units, while, finally, delineating the most recent developments pertaining to the newly-introduced codes applied by certain energy markets on low voltage network, particularly those related to PV systems. Secondly, while considering the implementation of the latest grid codes into low voltage PV systems, as well as conventional generators’ response to higher voltage levels with reference to meeting the FRTC demand, this dissertation investigates low voltage PV systems’ behavior when controlled in such a way that their operational response during disturbances simulates that of a conventional generator. To this end, the investigation parameters used consist in the penetration level, dispersion, as well as the impedance of inductance that is included in the dispersed PV generators’ converter.This investigation stems from the formulation of analytical calculation equations of bus voltages and PVs converter current, when these are faced with permanent three-phase short circuits faults, in any one of the bus bars composing a radial distribution network. For the needs of this research, PV units are regarded as models of voltage sources in series with the impedance included in the converter through which they are connected to the network. The second step of this investigation pertains to the exploration of the parameters’ impact on the above-mentioned electric quantities and to the deduction of important conclusions related to the selection of these parameters, as well as the possibility of achieving the FRTC demand.Having established the aforementioned criteria and goals, and with a view to exploring the possibility of achieving a high level penetration of PV low voltage units into a radial distribution network, this research proceeds to suggest an optimized PV unit design, whose parameters consist in converter-included impedance value, as well as penetration levels. In this way, is ensured that, should permanent fault in any of the bus bars comprising a distribution network occurs, the PV unit points of common coupling will be functioning at the highest possible voltage. Thus, in consonance with FRTC demand, the duration of the PV unit’s connection to the network will be extended to its greatest possible length. In addition, taking the optimization results, as well as the restrictions imposed with reference to PV inverter contribution in case of fault, into consideration, this research delineates the appropriate converter design, so that the demands raised by the new grid codes are met. Founded on extensive bibliographical research, the next stage of this work consists in the design, modelling and analysis of a control methodology that may apply to a complete PV system, consisting of a 6kWp PV array and inverter, connected to a low voltage distribution network, and supplying a load. This stage commences with a description and simulation of the PV system synchronization and control process in normal operating conditions, followed by the determination of the system’s proper functioning in both stable and changing environmental conditions. In conjunction with the conclusions drawn during the investigation of PV systems’ performance as conventional synchronous generators in case of fault, this thesis promotes a significant improvement of the initial control process, in order for the PV system to respond appropriately in transient situations that result from fault in the points of common coupling. The differentiated control method in question ensures the PV system’s equable operation—within the inherent restrictions imposed by PV arrays and converter behavior—while simultaneously satisfying the FRTC demand, particularly in relation to reactive power injection at the coupling point in case of fault. Furthermore, this study extends to the system’s transient response in various cases of fault and diverse impedance values, as well as during the reinstatement of the initial operating levels. In addition, an account of the conclusions drawn is provided with a view to clearly highlighting the suggested method’s advantages in comparison to other such processes presented in related literature. Considering diverse values of the PV inverter-included impedance, this research is concluded by simulating and analyzing the performance of multiple dispersed PV units that are connected to a low voltage radial distribution network, following the implementation of the suggested control methodology. The conclusions drawn from this analysis underline the positive effects resulting from the implementation of the suggested, improved control process in relation to both the PV systems’ response and the extension of their connection to the network in case of fault.

Degree

thesis:*
Grantor dc:publisher
University of Patras
Year dc:date
2016

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Perpinias, Ioannis
  • Περπινιάς, Ιωάννης

Subjects

dc:subject × 34

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/37396

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Perpinias, Ioannis; Περπινιάς, Ιωάννης. Συμβολή στο σχεδιασμό ηλεκτρονικών μετατροπέων ισχύος για διασυνδεδεμένα με το δίκτυο χαμηλής τάσης φωτοβολταϊκά συστήματα. University of Patras, 2016. http://hdl.handle.net/10442/hedi/37396