Back to search

University of Ioannina

Φασματοφωτομετρικός μικροπροσδιορισμός σιδήρου και κοβαλτίου με κυανέρυθρη ν-οξίνη αλιζαρίνη σε φυτικά και ζωικά δείγματα

Abstract

dc:description

Iron is the sixth most abundant element in the world and accounts for about 5% ofthe earth's crust, contrary to cobalt which is only 0.0029%.Iron is in the 4th period and the 8th group of the periodic table, with 26 atomicnumber and 55.847 atomic mass. The usual oxidation numbers are +2 and +3. It is agray-white or grayish metal sufficiently malleable and ductile, softer than aluminum thatcan obtain any desirable shape, however it is very sensitive to the presence of oxygenand water. The boiling point of pure iron is 2,862 °C and the melting point 1,538 °C. Themajor mineral metals of iron are, Magnetite, Hematite, Limonite, Siderite and Chamositis.Combining these features with the low cost, steel and various alloys of iron, is now widelyused in modern industry.In addition, iron is the most abundant transition metal and has the most biologicalroles of any other element. Fe2+ is an essential trace element used by almost all the livingorganisms, while Fe3+ is well absorbed. In the human body, iron is transferred in the bloodby the transferrin and stored in the liver, spleen and bone marrow. Furthermore, iron is noteasily excreted from the human body, so it can be accumulated to toxic concentrations,which can even cause death.Cobalt is in the 4th period and the 9th group of the periodic table, with 27 atomicnumber and 58.933 atomic mass. The usual oxidation numbers are +2 and +3. The boilingpoint of pure cobalt is 2,927 °C and the melting point 1,495 °C. Apart from nickel and iron,cobalt is one of the three naturally magnetic elements. The major mineral metals of cobaltare, Kovaltitis, Sfairokovalitis, Erythritis, Soffloritis and Skoutterouditis.Previously, compounds of cobalt had used in dying, giving blue color to the glass,in enamels, in ceramics and painting. Nowadays, cobalt isotopes, as 57Co, are used inmedicine, with the testing control-Schilling, in research as a source at the Mössbauerspectroscopy and also in fluorescent X-rays devices, while the isotope 60Co, a radioactivemetal, which its half-life is 5.27 years, is used in radiotherapy. Finally the isotope 59Co,can be used in the manufacture of a weapon, known as "cobalt bomb".Cobalt is an essential dietary trace element for all animals. It is the active center ofcoenzymes called cobalamins and the most famous example of these is vitamin B12. Vitamin B12 is essential for the proper functioning of cells, keeps the nervous systemhealthy, increases the body energy and reduces the irritability. It also improvesconcentration, memory and balance. Vitamin B12 is essential during the rapid separation of cells, is useful for the folic acid release and thus helps to helps in red blood cell formation. Finally, vitamin B12 is found almost exclusively in animal’s flesh and animal products.In case of iron and cobalt deficiency, there are replenishment formulations to refillthe Recommended Daily Allowance (RDA) limits. Deficiency in iron and cobalt mainlyleads to anemia with the known symptoms like exhaustion, weakness etc. In addition, deficiency in cobalt-vitamin B12 leads to neurological problems and it is difficult to bedetermined directly, because of the high levels of accumulation.For these reasons, the determination of the iron and cobalt percentage in drinkingwater, food, pharmaceutical products and biological samples, is necessary to avoidaccumulation of these metals while has attracted great interest, using many differenttechniques of instrumental analysis as GFAAS, SPS, HPLC, ICP, V, P, F and UV / Vis,which was used in our laboratory.In this direction, the choice of Acid Alizarin Violet N (AAVN-AVN) and 1,10phenanthroline as possible coupling reagents, gave a very strong reaction with iron andcobalt. The parameters studied for method optimization were, the ligant concentration, pH,time and the reaction temperature and the affinity between the metal and the ligand.The optimum pH value for the reaction of iron and cobalt with ligands was studied ina pH range between 3.4 and 5.9, whereas pH 5.0 was the optimal value. Α buffer solutionof acetic acid 0.2 M and sodium acetate 0.2 M was used for this purpose in order to avoidundesirable deviations of the measurements. Ιt was found that the complexation betweenligands and metal ions, at room temperature, was not complete, so a water bath at 60 °Cfor 30 minutes was needed. Stock and working solutions were prepared either in distilledwater or in 0.1 M HNO3 and was always fresh. However, repeated measurements ofabsorption standards AVN, demonstrated that they were stable for 10 to 13 days.The optimum AVN concentration, for concentration range of iron, 1 to 5 μΜ, wasfound to be from 30 μΜ to 90 μΜ. The experimental concentration of AVN chosen was 50μΜ. For complexes AVN-Fe3+, 1,10 phenanthroline-H3NOCl-Fe2+ and AVN-Co2+, theminimum-maximum limits of determination of Fe3+, Fe2+ and Co2+ are: 0.2 to 36 μM, 0.2 to24 μM and 0.2 to 160 μM. However, for complexes AVN-Fe3+ and AVN-Co2+ showed theexistence of six complexes between metal ion (M) and ligand (L), as follows: ML, ML2, ML3, ML4, ML5, ML6. Various metal ions, found in several samples, preventing the determination of ironand cobalt giving errors which are due to the absorption of the matrix (matrix effect). Forthis reason, it was chosen to use the selected Ιsosbestic Point (IS) of the complex AVN-Al3+, in order to remove the obstruction of ions Al3+ and AlPO4. Applying the Beer law formixtures, the interference effect of these ions are decreased to a satisfactory extent.By using the calibration curve of known addition method and applying the method ofleast squares, the variations in absorption in relation to the concentration of iron andcobalt applied to the determination of these metal ions in the reference samples as PrawnGBW08572, the Wheat NCS ZC73009 and LP-Prawn (reference sample which wasprepared in the laboratory). The limit of detection (LOD) and quantification limit (LOQ) forFe3+ in standard samples examined is 0.97×10-8 and 2.91×10-8 M, for Fe2+ is 5.36×10-8and 1.62×10-7 M and for Co2+ is 0.3×10-7 and 0.9×10-7 M respectively. The LOD and LOQof the methods, calculated from the standard deviation of all points of the curve.In conclusion, with this proposed method, the theoretical and actual detection limit isnow about 2, 3 times lower. So, the prevailing hitherto perception about the errorabsorption spectrophotometry should be revised, since proved that the relative error isgreater in smaller concentrations or in greater transmittance. Namely, it can be developedaccurate and sensitive spectrophotometric methods, measuring at the top of the scale ofthe transmittance (T = 99%).

Degree

thesis:*
Grantor dc:publisher
University of Ioannina
Year dc:date
2014

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Palios, Anastasios
  • Παληός, Αναστάσιος

Subjects

dc:subject × 18

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/37424

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Palios, Anastasios; Παληός, Αναστάσιος. Φασματοφωτομετρικός μικροπροσδιορισμός σιδήρου και κοβαλτίου με κυανέρυθρη ν-οξίνη αλιζαρίνη σε φυτικά και ζωικά δείγματα. University of Ioannina, 2014. http://hdl.handle.net/10442/hedi/37424