University of Patras
Φυσικομαθηματική μεθοδολογία για τον προσδιορισμό νέων χαρακτηριστικών παραμέτρων της οστεοπόρωσης χρησιμοποιώντας ακτινοβολία Χ δύο ενεργειών (KVP) με στόχο τη βελτιστοποίηση της διάγνωσης και της χρονικής παρακολούθησης της νόσου
Abstract
dc:descriptionNon-invasive dual energy methods have been used extensively on osteoporosis diagnosis estimating parameters, such as, Bone Mineral Density (BMD) and Bone Mineral Content (BMC).The aim of this thesis is to use the Calcium-Phosphorus masse ratio (Ca/P) as a quality bone health assessment index. The mass ratio Ca/P is determined by the dual-energy X-ray method using either linear model equations or non-linear, polynomial models. In the first approach of Ca/P determination, an X-ray dual energy method optimized for the accuracy and precision of bone Ca/P mass ratio determination was developed. A simulation study, based on analytical modeling was performed in order to obtain the optimized irradiation parameters (X-ray tube high voltage, filter material and thickness). The simulation study was followed by experimental evaluation of the method using the optimized parameters. The detector used was a CdTe based energy discriminating photon counting detector, combined with a narrow pencil X-ray beam, suitably modified with K-edge filtering, to obtain two separate energy peaks. This method revealed better precision and accuracy in Ca/P ratio determination compared to previous studies. In the second approach of Ca/P determination, the use of a nonlinear X-ray dual energy approximation for determining the Calcium-to-Phosphorus (Ca/P) mass ratio was investigated. The dual energy simulated data were obtained using variable Ca and PO4 thicknesses on a fixed total bone thickness. The fitting coefficients of inverse equations were determined by applying the least-squares estimation on data calculated from analytical model simulation. Linear, quadratic, and cubic functional forms of inverse equations were investigated. Transmission measurements of six bone phantoms with different total thicknesses and Ca/P mass ratios were obtained to evaluate the method. The determination of accuracy and precision of the methods in experimental conditions indicated that the bone Ca/P determination can be used to discriminate the stages of bone diseases and to be applicable for clinical practice.
Degree
thesis:*- Grantor dc:publisher
- University of Patras
- Year dc:date
- 2016
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Sotiropoulou, Panagiota
- Σωτηροπούλου, Παναγιώτα
Subjects
dc:subject × 12- Λόγος μαζών Ca/P των οστών
- Μέθοδος διπλής ενέργεια ακτινών Χ
- Γραμμικές εξισώσεις εξασθένησης
- Πολυωνυμικά μοντέλα προσέγγισης εξισώσεων
- Ca/P bone mass ratio
- Χ-ray dual energy method
- Linear attenuation equations
- Polynomial models of dual energy equations
- Ιατρική και Επιστήμες Υγείας
- Άλλες Ιατρικές Επιστήμες
- Medical and Health Sciences
- Other Medical Sciences
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/37706