National and Kapodistrian University of Athens
Δοσιμετρία ασθενών κατά τις επεμβατικές ακτινολογικές εξετάσεις με τη χρήση λογισμικού προσομοίωσης Monte Carlo
Abstract
dc:descriptionThe evolution of interventional radiology has designated as an alternative option that replaces open surgery. The main disadvantage of interventional radiology practices is the usage of ionizing radiation, in order to visualize the region of interest, resulting in the necessity of optimization in the practices to reduce the potential risk as the absorbed dose can be significantly higher than normal radiographic examinations. Percutaneous transhepatic billiary drainage – PTBD, chemoembolizations, diagnostic subtracted angiography (DSA) of abdominal aorta to lower libs are interventional practices that the patients’ radiation burden is in high levels. The main purpose of this thesis is the dosimetric study of the above referred interventional procedures. The used dosimetric parameters were DAP, equivalent organ doses HT, effective dose E, organ dose and effective dose conversion factors and the risk of exposure-induced cancer death (REID). Doses and conversion factors were calculated simulating the interventional procedures with Monte Carlo codes. The used Monte Carlo codes were MCNP5 and PCXMC2.0. There were used two codes in order to increase the accuracy of the calculations.The mean DAP values of the male (n=20) and female (n=23) group that underwent in PTC were 4500±2600 και 5500±3300 cGycm2, respectively. The effective dose conversion factors were 1,1 10-3 and 1,2 10-3 for both group calculated with MCNP5 and PCXMC2.0 codes, respectively. The mean calculated REID% values were 0,015±0,013 και 0,022±0,016, for the group of males and female, respectively. The mean DAP of the group underwent in chemoembolization (n=32) was 8360 ± 5530 cGycm2, the mean calculated REID% value was 0,052±0,036 and the effective dose conversion factors were ήταν 1,4 10-2 και 1,6 10-2 calculated with MCNP5 and PCXMC2.0 codes, respectively. The mean DAP of the group underwent in DSA (n=30) was 5075.1±2420.4 cGy cm2, the mean calculated REID% was 0,016±0,0067 and the effective dose conversion factors were ήταν 5,1 10-4 και 5,7 10-4 calculated with MCNP5 and PCXMC2.0 codes, respectively.The dosimetric study of complex interventional procedures contributes to characterization of the radial risk and optimization of the used techniques since the radiation burden is higher than the classic radiographic examinations.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2016
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Karavasilis, Efstratios
- Καραβασίλης, Ευστράτιος
Subjects
dc:subject × 12Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/37727