National and Kapodistrian University of Athens
Επίδραση της ακτινοβολίας ιόντων σιδήρου στις δομικές και μαγνητικές ιδιότητες υμενίων σιδήρου
Abstract
dc:descriptionThis thesis was carried out within the frame of the “Fusion Technology” research programaiming to the development of new structural materials for the future fusion reactor. The candidate materials are based on Fe-Cr alloys, which at this stage are unable to withstand the operating conditions of the future fusion reactor. Due to the high neutron fluxes and temperatures achieved inside the reactor, developing highly resistant materials is mandatory. To this end, it is essential to study and understand the radiation damage mechanisms in the fusion environment. In order to materialize this objective, using fission reactors to study the effect of irradiation on materials proves to be insufficient owing to significant differencies in the energy spectrum between fission and fusion neutrons. Nevertheless the research on neutron radiation damage can be implemented by appreciating that the dominant damage arises from Primary Knock-on Atoms (PKA). As the neutrons hit the iron target, their energy is transferred to the primary knock on iron atoms that propagate the damage inside the material through collision cascades. It was chosen to utilize the above expressed viewpoint self irradiating iron as it is the main constituent of Fe-Cr alloys; the candidate materials of the future fusion reactor. The energy of the Fe+ was defined to 490 keV as this is the mean energy of the Fe PKA produced by 14 MeV fusion neutrons impinging on iron.Simulations of the 490 keV iron ion irradiation of iron have shown that the ions penetrate the target at a depth of 400 nm. Therefore, thin films are the appropriate system to study the radiation damage mechanisms in iron. During irradiation the mechanisms present are two: the ion implantation and the iron atom displacement, whose contribution varies as a function of the film depth. To understand the damage induced by each of these mechanisms, iron films of 60 nm and 200 nm thickness were fabricated using the technique of DC Magnetron Sputtering. The principal mechanism taking place in 60 nm films is iron atom displacement, while in 200 nm both mechanisms contribute.Iron samples were irradiated with 490 keV iron ions at the JANNuS facilities at CEA, Saclay of France; irradiation doses of 2×10^14 – 1.34×10^17 ions/cm2 were achieved for different ion fluxes. These ion doses correspond to 0.5 – 341 displacements per iron atom. The samples were characterized berofe and after irradiation, using the experimental techniques of X-ray diffraction and reflectivity for the study of their structural properties as well as polarized neutron reflectivity and hysteresis loop measurements investigating their magnetic properties.From the results of the above measurements follows that iron ion irradiation affectssignificantly the structure and magnetism of iron in both film thicknesses. Both the lattice constant and the grain size increase monotonically with dose. Initially an abrupt increase of the lattice constant and the grain size is observed up to a certain dose beyond which both properties approach slowly the saturation. It is concluded that in both film thicknesses, the lattice constant and the grain size follow a universal behavior with irradiation dose. Furthermore, the coercive field of the films is reduced exponentially, making iron magnetically softer, with irradiation.For the first time the effect of irradiation and its induced defects on iron magnetic moment has been determined, behaving differently for the two film thicknesses. In the case of 60 nm films a major increase of magnetic moment per iron atom was observed, from 2.1 μB/at before the irradiation to 2.5 μB/at for the highest dose of 72 dpa. This behavior is attributed to the creation of vacancies and vacancy clusters which are responsible for the increase of magnetic moment according to the predictions of theoretical studies. Furthermore the time relaxation effect of magnetic moment has been observed returning to its prior irradiation value 24 months after irradiation. In the case of 200 nm films, irradiation induces a depth dependent magnetic profile consisting of two sublayers. The top Fe sublayer has a magnetic moment higher than that of the Fe before the irradiation whereas the bottom sublayer lower. This behavior is connented with the effects of Fe+ irradiation, i.e. in the top sublayer, radiation damage mainly occurs whereas in the bottom one, implantation of impinging Fe+ ions. The magnetic moments of the two sublayers have a non-monotonous variation with irradiation dose depicting a maximum for the top sublayer and a minimum for the bottom one at 96.2 dpa. The magnetic moment enhancement/ reduction is examined in relation with the atomic volume variation in the case of atom displacements and/ or implantation effects.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2016
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Papamihail, Aikaterini
- Παπαμιχαήλ, Αικατερίνη
Subjects
dc:subject × 14Rights
dc:rights- Statement dc:rights
-
- BY
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/37750