Aristotle University Of Thessaloniki (AUTH)
Η φλεγμονώδης αντίδραση από σύγχρονα βιοαπορροφήσιμα οστικά εμφυτεύματα ως παράγοντας περιορισμού της λοίμωξης στο σημείο οστικής εμφύτευσης: πειραματική μελέτη σε κονίκλους
Abstract
dc:descriptionMetal implants make tissues more susceptible to bacteria settlement allowing bacterial adhesion on their surfaces by creating an extracellular biofilm which prevents penetration and action of antibiotics, making implant removal necessary eventually. The type of implant may affect this process. This experimental study aims to find out the relation between the inevitable aseptic inflammatory reaction caused by bioabsorbable implants and the resistance of them to infection. All the bioabsorbable implants which are currently used in Surgery(knees, shoulders, hands, traumatology, spines, max-facs surgery) are based on lactic and glycolic acids and their polymers. The most widely used is the L-isomer of lactic acid(PLLA) which has excellent biocompatibility is degraded slowly. 127 new Zealand white rabbits were used in this experiment. Pseudomonas aeruginosa derived from a patient with chronic osteomyelitis was used. After overnight growth an inoculum of 2×10⁸ CFU was prepared and applied to rabbit femoral diaphysis in groups 2,4,6,8, according to Norden and Kennedy model.Group 1: No intervention. Group 2: Simple bacteria instillation without any other intervention. Group 3: Surgical exposure of the rabbit femur without any other intervention. Group 4: Surgical exposure of the rabbit femur and application of the inoculum. Group 5: : Surgical exposure of the rabbit femur and application of a 2 hole titanium phalangeal plate. Group 6: Surgical exposure of the rabbit femur , application of a 2 hole titanium phalangeal plate and bacteria inoculum instillation. Group 7: Surgical exposure of the rabbit femur and application of a 2 hole bioabsorbable phalangeal plate. Group 8 : Surgical exposure of the rabbit femur, application of a 2 hole bioabsorbable phalangeal plate and then bacteria inoculum instillation. The criteria applied for infection development were the clinical findings, the ESR and CRP elevation and the histological findings. The application of Fisher’s exact test to groups 5 and 7 showed that there is no statistically significant difference between the two groups with regards to infection development. The chi-square test modified to Yates showed that again there is no statistically significant difference between the groups 6 and 8 with regards to infection development. The fixation with biodegradable implants seems more resistant to pseudomonas osteomyelitis in new Zealand white rabbits. However the development of aseptic inflammatory response is quite frequent. The wide use of bioabsorbable implants as fixation devices in Orthopaedic surgery can not be supported.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2016
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Savvidis, Panagiotis
- Σαββίδης, Παναγιώτης
Subjects
dc:subject × 6Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/37938