National Technical University of Athens (NTUA)
Μοντελοποίηση και πειραματική αξιολόγηση συστημάτων εξατμιστικής ψύξης
Abstract
dc:descriptionThis PhD thesis focuses on evaporative cooling technology, especially the Maisotsenko cycle (M-cycle); this cycle is the most advanced implementation of evaporative cooling and promises much higher efficiency than conventional techniques, using less water and, more importantly, the best quality of supply air to the cooled space. The thesis is structured starting from the description of current technology and building a solid theoretical background for better understanding of the heat and mass transfer phenomena; thereby familiarity with the operation of evaporative cooling systems, special underlying principles, sizes quantifying their performance and fundamental thermophysical phenomena that determine wholly behavior are ensured. The connection with the earlier research work is done by the development of a computational model on direct evaporative coolers, adding an additional functional parameter (water temperature). Thereafter, M-cycle is analytically developed, exploring how it is feasible operation and high performance and, based on a experimental rig, the behavior in various environment conditions is studied; the experimental procedure confirms the construction standards, not only in terms of thermodynamic characteristics of the supply air (at a temperature lower than that of the corresponding wet bulb temperature and the humidity ratio in common with that of the environment) but also in terms of water consumption (approximately 2.6kg evaporating water per kWh of cooling). To study and configuration cycle, full thermodynamic energetic model is structured, which follows the basic geometry of the cycle and is based on combining energetic and thermorfluid methods; customization confirms the independence of M-cycle efficiency instead of ambient conditions and negate in practice, some assumptions were maintained geometric configuration (in relation to the air flows through the duct). An additional cylindrical configuration achieves even lower water consumption. Finally, consider the applicability of evaporative cooling as an alternative method of producing building air conditioning, by using rainwater, in order not to burden of potable water.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2014
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Tertipis, Dimitrios
- Τερτίπης, Δημήτριος
Subjects
dc:subject × 12Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/38048