Back to search

University of Thessaly (UTH)

Εκτίμηση της αποτελεσματικότητας των αρθρωτών στροφικών αρθροπλαστικών γόνατος, μελετώντας μεσοπρόθεσμα την εφαρμογή της ενδοπρόθεσης solution RT

Abstract

dc:description

In this study, out of 115 challenging arthritic knees (in 97 patients), in which from 1996 until 2001 the “Solution RT” rotating–hinge knee prosthesis had been implanted, 85 knees (in 70 patients) were available for follow-up that reached a mean of 8.1 years (range, 6.2-10), using the Knee Society Knee Score System. Later on, in a mean of 13.8 years (range, 12-17.6) follow-up by phone, searching for complications and revisions was performed.Immediate postoperative results were satisfactory. Complications like infections, loosening and periprosthetic fractures were within so far reported range. However, patellofemoral complications occurred quite frequently. In the follow-up period several major mechanical complications were encountered, as jamming and impingement of the hinge mechanism but also a case of a twice broken polyethylene insert. These events were the reason to conduct a biomechanical study. Retrievals were analyzed and a cascade of events were noted in knee hyperextension so that abnormal motion can result, leading to the deformation or even breakage of the polyethylene insert and impingement on the hinge mechanism. Using finite element analysis (FEA) and applying the anthropometric data of the patient with the broken liner in static hyperextension loading, it was calculated that stresses on the liner exceeded four times the material’s resistance against deformation and three times against breakage. The design of the prosthesis was poor in resisting high hyperextension loading applied by heavy patients if genu recurvatum resulted postoperatively. Survival rate of the prosthesis was 94.1% at a mean of 8.1 years and 92.9% at a mean 13.8 years.Amongst the statistical correlations found in this study, obesity was a statistically important predisposing factor for mechanical and overall failures. After some years the implant had been marketed, it was recommended not using this implant in obese patients and after a takeover of the company this device is not available at present.

Degree

thesis:*
Grantor dc:publisher
University of Thessaly (UTH)
Year dc:date
2016

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Kafidas, Dimitrios
  • Καφίδας, Δημήτριος

Subjects

dc:subject × 10

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/38426

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Kafidas, Dimitrios; Καφίδας, Δημήτριος. Εκτίμηση της αποτελεσματικότητας των αρθρωτών στροφικών αρθροπλαστικών γόνατος, μελετώντας μεσοπρόθεσμα την εφαρμογή της ενδοπρόθεσης solution RT. University of Thessaly (UTH), 2016. http://hdl.handle.net/10442/hedi/38426