University of Thessaly (UTH)
Structural behavior of liquid storage steel containers under strong dynamic excitation
Abstract
dc:descriptionLiquid containing tanks made of steel material are used in water storage and distribution systems, as well as in industrial plants for the storage and/or processing of a variety of liquids and liquid-like materials, including oil, liquefied natural gas, chemical fluids and wastes of various forms. The present research refers to ground-supported tanks and does not refer to underground or elevated tanks.Tanks can be categorized as anchored and unanchored, if they are constructed with or without anchor bolts respectively. In the case of a strong seismic event unanchored tanks are likely to exhibit uplifting of their bottom plate, when the magnitude of the overturning moment exceeds a threshold value. During a strong seismic event, liquid storage tanks may exhibit significant damages. Their structural response under strong seismic loading constitutes an important issue for safeguarding the structural integrity of industrial facilities. Typical steel tank damage can occur in the following forms: (a) buckling of the shell, because of excessive axial (meridional) compression due to overall bending of the structure under transverse seismic action, (b) damage of the roof and the top part, caused by sloshing of the upper part of the contained liquid when there is insufficient freeboard between the liquid surface and the roof, (c) base plate fatigue or/and fracture due to uplifting of the tank, (d) anchor bolt failure in the case of tanks anchored to the ground (e) shell damage at nozzle areas due to non-flexible connections with piping and other accessories, due to the inability of these elements to accommodate the deformations of the flexible shell. Shell buckling usually takes the form of “diamond shaped” or “elephant’s foot” buckling that appears at a short distance above the base and usually extends around most or of the entire circumference. In previous earthquake events, damages of various severity have been reported, e.g. from fracture of a pipe that created only slight leaks on minor repairs (damage to an overflow pipe) to complete loss of tank content.Seismic analysis of liquid-containing tanks differs from typical civil engineering structures (i.e. buildings and bridges) mainly because of two reasons: first, during seismic excitation, liquid inside the tank exerts hydrodynamic force on tank walls and base, and second, tanks are generally less ductile and have significantly lower redundancy. The present dissertation refers to the response of liquid storage tanks under strong dynamic excitation, with emphasis on seismic response. In particular, it emphasizes in two major phenomena which are examined extensively; (a) elephant’s foot buckling and (b) base uplifting of unanchored tanks. The research is aimed at better understanding of tank mechanics and response, and defines a performance-based design framework that can be used for reliable development of vulnerability and assessment of seismic risk. The results of the present research can be also employed in possible future amendments and revisions in existing seismic design provisions. Modeling of tank structural behavior is performed using an efficient combination of detailed finite element models and simplified numerical techniques, which offer a simple and efficient tool for tank dynamic analysis. Elephant’s foot buckling is examined in Chapter 3 using three-dimensional and axisymmetric nonlinear finite element rigorous tools, in terms of buckling and post-buckling, considering material and geometric nonlinearities, accounting for initial imperfections for hydrostatic pressure and for internal pressure levels up to a significant percent of yield pressure. Two types of imperfections are considered: (a) imperfections from real measurements in an existing tank, which are of random shape and (b) axisymmetric imperfections in the form of an initial bulge at the bottom of the cylinder around the circumference of the cylinder. Special emphasis has been given on the development of local stresses and strains at the buckled area, in the pre-buckling and the post-buckling configuration. The numerical results have been compared with the predictions from the relevant provisions of EN 1993-1-6 and EN 1998-4. Lastly, the effectiveness of strengthening the tank with FRP wrapping against elephant’s foot buckling failure is also examined.
Degree
thesis:*- Grantor dc:publisher
- University of Thessaly (UTH)
- Year dc:date
- 2016
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Vathi, Maria
- Βάθη, Μαρία
Subjects
dc:subject × 19- δεξαμενές αποθήκευσης υγρού
- δυναμική διέγερση
- Σεισμική απόκριση
- ανασήκωμα πάτου δεξαμενής
- Σχεδιασμός με βάση την επιτελεστικότητα
- Liquid storage tanks
- Dynamic excitation
- Seismic response
- elephant's foot buckling
- uplifting
- Performance based design
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Πολιτικού Μηχανικού
- Επιστήμη Μηχανολόγου Μηχανικού
- Μηχανική Υλικών
- Engineering and Technology
- Civil Engineering
- Mechanical Engineering
- Materials Engineering
Rights
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/38431