dc:descriptionThe development of dedicated computational tools to accurately predict heat transfer and energy storage phenomena in buildings and building components containing PCMs is essential. Recently, research has been directed from PCM component examination to full scale test cases (cells or model rooms with one or more PCM walls) covering experimental data and/or numerical predictions, primarily aiming to evaluate the energy performance of PCM passive applications. Experimental studies show a reduction of energy consumption when PCM wallboards are installed in test rooms, reaching approximately 15% in total heating loads and achieving a maximum cost saving of about 30% over conventional non-PCM base-case. Focusing on lightweight buildings, experimental data showed that PCM wallboards contributed to the thermal comfort of occupants and smoothed out the wall temperature fluctuations.The aim of this thesis is to provide a holistic approach to the modelling of the non-linear thermal phase change process of a PCM and to evaluate the thermal behaviour of a purposely built full scale lightweight building combining a hybrid steel frame with dry wall systems incorporating PCMS. This is accomplished by using a dedicated simulation tool, based on a coupled TRNSYS and MATLAB solver. The methodology used for the introduction of the PCM simulation in an existing computational tool is developed in this thesis. The goal is to have a tool that allows assessment of the PCM behaviour along with the analysis of the thermal behaviour of a building, taking into account all the features and characteristics (e.g. shading, occupancy profiles, location, HVAC etc) of a full scale building in operation.The solver is firstly validated against experimental data obtained through a 12-month monitoring period of the house, as the temperature and heat flux through building components along with the indoor air temperatures are continuously monitored. In order to assess the energy demand of the building and to quantify the PCM effect, the annual cooling loads are under examination. The building is located in Amfilochia, Greece and PCM gypsum boards have been used to cover all the internal side of the walls as well as the internal partitions of the building. In the computational comparative study carried out in this thesis, the PCM plasterboards are replaced by plain gypsumboards, in order to evaluate the PCM impact in the annual cooling demands of the building and the span of the cooling period. Parametric studies are carried out in order to investigate the possibility of higher energy savings and to determine their impact on the energy efficiency of the building. The parameters under investigation are: i) the phase change temperature range of the PCM, which is in the plasterboard, ii) various parameters of the building, such as infiltration and humidity, iii)occupancy profiles and use of the building and iv)different climate conditions. The optimized scenarios, for different combinations of the aforementioned parameters, are shown at the end of the simulations.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2014
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Stamatiadou, Marianna
- Σταματιάδου, Μαριάννα
Subjects
dc:subject × 17- Ενεργειακή προσομοίωση κτηρίου
- Μοντέλα προσομοίωσης
- Υλικά αλλαγής φάσης
- Αποθήκευση ενέργειας
- Εξοικονόμηση ενέργειας
- Κτήρια ελαφριάς κατασκευής
- Συνθήκες λειτουργίας κτηρίου
- Building energy simulation
- Simulation models
- Phase change materials
- Energy storage
- Energy saving
- Building occupation profiles
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Μηχανολόγου Μηχανικού
- Engineering and Technology
- Mechanical Engineering
Rights
dc:rights- Statement dc:rights
-
- BY_NC_SA
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/38640