Institutes outside Greece
Effects of cementation on exposed luting agent profile at implant-supported crowns
Abstract
dc:descriptionExposed cement surface at restoration margin is difficult to control, and poses threat to the health of peri-implant tissues. Therefore, the purpose of this in-vitro study was to examine quantitatively the influence of combinations of different levels of initial marginal discrepancy (MD), different cement types (CT), and finishing techniques (FT), utilized to remove excess cement, on linear characteristics of the exposed marginal cement surface.The method was developed in a pilot study. Next, in a 2^3 full factorial and randomized experimental design with 15 replications, each of the 120 identical two-component samples was treated with a combination (eight groups) of the 3 two-level factors (CT, MD, FT). Samples were prepared in standardized ways and negative replicas were produced, which were stained and sectioned in six pieces, perpendicular to the margin. Images of sections, captured in a stereomicroscope coupled with a digital camera, were evaluated with image analysis software. Response variable was the averaged proportion of the actual cement profile increase, compared to the ideal cement profile of the examined sample (SaCPIR).Results of this study revealed significant differences between the eight tested treatment combinations (n=14) (ANOVA, α=0.05). Samples of both discrepancy levels, cemented with the luting composite and excess cement removed after cement setting had the lower SaCPIR scores (P<.05). The factorial design analysis showed that SaCPIR was mainly influenced by the initial marginal discrepancy level (P<.0001) and the finishing technique (P<.0001). Thereafter, increased initial marginal discrepancies, within clinically acceptable limits, and excess cement removal with a plastic scaler after setting, generally resulted in smaller increases of the actual cement profile in comparison to the ideal cement profile of the examined crown. Furthermore, multiple significant interaction effects between the examined factors were revealed (P<.05).Crowns with acceptable marginal fit, cemented with a luting composite and excess cement removed after setting, resulted in the smallest deviation from the ideally cemented restoration. Additionally, the complexities of cementation procedures that affect linear characteristics of the exposed marginal cement surface were clarified in this study.
Degree
thesis:*- Grantor dc:publisher
- Institutes outside Greece
- Year dc:date
- 2015
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Villias, Aristeidis
- Βίλλιας, Αριστείδης
Subjects
dc:subject × 26- Εμφυτευματολογία
- Τεχνητό κολόβωμα
- Στεφάνη
- Οριακή εφαρμογή
- Συγκολλητικός παράγοντας
- Περίσσεια κονίας
- Προφίλ επιφάνειας κονίας
- Τυχαιοποιημένο πολυπαραγοντικό πείραμα
- Ψηφιακή ανάλυση εικόνας
- Επιφάνεια κονίας
- Implantology
- Abutment
- Growth
- Marginal fit
- Luting agent
- Excess cement
- Cement surface profile
- Randomized factorial design
- Digital image analysis
- Cement surface
- Ιατρική και Επιστήμες Υγείας
- Επιστήμες Υγείας
- Ιατρική Βιοτεχνολογία
- Medical and Health Sciences
- Health Sciences
- Medical Biotechnology
Rights
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/38715