Back to search

University of Patras

Διόρθωση της εξασθένησης της γ-ακτινοβολίας (attenuation correction) μέσω υπολογιστικής αξονικής τομογραφίας (CT) χαμηλής ευκρίνειας σε τομογραφικές (SPECT) σπινθηρογραφικές μελέτες αιμάτωσης μυοκαρδίου: διαγνωστική και προγνωστική αξία

Abstract

dc:description

Purpose: To investigate the diagnostic and prognostic value of photon attenuation correctionthrough maps derived from low-dose/low-resolution CT in coronary artery disease.EXPERIMENTAL PARTMaterials and Methods: SPECT/CT 201Tl and 99mTc imaging was performed on a Data Spectrumtorso phantom, firstly without “myocardial” defects (assessment of overall and regional imageuniformity and counts) and afterwards with the insertion of “subendocardial” and “transmural”defects (measurement of defect FWHM and contrast); subsequently, attenuation corrected (AC) &non-corrected (NAC) images were compared pairwise as regards the aforementioned parameters.Results: AC was favoured in the measurements without defects by increasing image uniformity andoptimizing inferior-to-anterior wall count ratio. When defects were imaged, AC was superior at theassessment of FWHM whereas NAC achieved better defect contrast.DIAGNOSTIC PARTMaterials and Methods: One-hundred and twenty patients with negative clinical markers for CADas well as 120 patients (90 males, 30 females) who were subjected to coronary angiography within60 days post-MPI (201Tl SPECT/CT) were retrospectively reviewed. AC & NAC images wereevaluated blindly both qualitatively and semi-quantitavely (Overall Summed Stress Score – SSS &Summed Difference Score – SDS as well as corresponding scores for LAD and RCA/LCx vascular domains). In the low-risk population, AC & NAC normalcy rate was assessed and in the populationwith angiographic reference sensitivity, specificity and diagnostic accuracy were calculated for bothAC & NAC MPI which were compared with the McNemar test. Finally, ROC curves were createdand the AUC were compared.Results: In the low-risk population AC increased normalcy rate while in the patients withangiographic correlation statistically significant results were obtained in the general and malepopulation in the RCA/LCx territory, where NAC was more sensitive and AC displayed higherspecificity without any significant results as regards diagnostic accuracy or ROC AUC comparisons.PROGNOSTIC PARTMaterials and Methods: 637 unselected patients underwent 201Tl MPI with CT-AC. AC & NACimages were interpreted blindly and summed stress scores (SSS) were calculated. Study endpointswere all-cause mortality and the composites of death/non-fatal acute myocardial infarction (AMI)and death/AMI/late revascularization. On the basis of the event rate distribution across SSS valuesSSS subgroups were created, Kaplan-Meier curves were drawn and compared by the use of theLogRank test and finally clinical and scintigraphic parameters were entered into the univariete and multivariate Cox regression model.Results: During a follow-up period of 42.3±12.8 months, 24 deaths, 13 AMIs and 28revascularizations were recorded. Prognostic SSS groups formed were: 0-4,5-13,>13 for NAC and 0-2,3-9,>9 for AC. Kaplan-Meier functions were statistically significant between NAC SSSgroups for all study endpoints. AC discriminated only between SSS 0-2 and >9 for death/AMI andbetween 0-2 and 3-9 for death/AMI/revascularization. In the univariate Cox regression, abnormalNAC achieved statistical significance for all endpoints whereas AC managed to do so only for SSS>2 & >9 regarding major and all events and for SSS>9 as regards all events. In the multivariatemodel, abnormal AC yielded no significance for either endpoint whereas abnormal NAC provedindependent from other covariates for the composite endpoints.CONCLUSION: Photon attenuation correction with the use of CT-derived attenuation maps doesnot seem to increase the diagnostic accuracy or prognostic value of myocardial perfusion SPECTand its non-selective utilization in clinical practice may lead to underestimation of coronary arterydisease and the subsequent risk of cardiac events.

Degree

thesis:*
Grantor dc:publisher
University of Patras
Year dc:date
2014

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Savvopoulos, Christos
  • Σαββόπουλος, Χρήστος

Subjects

dc:subject × 13

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/38735

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Savvopoulos, Christos; Σαββόπουλος, Χρήστος. Διόρθωση της εξασθένησης της γ-ακτινοβολίας (attenuation correction) μέσω υπολογιστικής αξονικής τομογραφίας (CT) χαμηλής ευκρίνειας σε τομογραφικές (SPECT) σπινθηρογραφικές μελέτες αιμάτωσης μυοκαρδίου: διαγνωστική και προγνωστική αξία. University of Patras, 2014. http://hdl.handle.net/10442/hedi/38735