National and Kapodistrian University of Athens
Συγκριτική μελέτη καθιερωμένου και ταχέος πρωτοκόλλου μιας ημέρας για την απεικόνιση της μυοκαρδιακής αιμάτωσης με τη χρήση Tetrofosmin-Tc 99m
Abstract
dc:descriptionINTRODUCTIONThe purpose of this research project was to comparatively evaluate the feasibility and performance of a fast myocardial perfusion imaging (MPI) protocol with the use of 99mTc .METHODS 68 patients underwent two sequential gated-SPECT, myocardial perfusion imaging studies (MPI) using treadmill exercise as a stressor. The first imaging sequence started at 15 (Early Imaging, T1 protocol) and the second at 45 (Late Imaging, T2 protocol) minutes post 99mTcinjection, at both stress and rest. For each protocol the following parameters were measured: counts over heart (H), liver (Liv) and subdiaphragmatic space (Sub), image quality, myocardial perfusion related variables (summed stress-SSS, summed rest-SRS and summed difference-SDS=SSS-SRS scores and ischemic myocardium mass) and left ventricular function related variables (global ejection fraction, end-diastolic and end-systolic volumes and scores of regional wall thickening and motion). Subsequently, these parameters were compared between the two protocols using appropriate statistical methods. Coronary angiography was performed in all patients within 2 months from MPI, and ROC analysis was used to compare the diagnostic accuracy for the detection of ≥50% diameter luminal stenosis.RESULTSOverall, image quality was graded as optimal-good in 65 (95%) of T1 and 67 (98%) of T2 studies (p=0,5). H/Liv and stress H/Sub ratios were similar, but rest H/Sub ratio was lower in T1 protocol (p=0,004). SSS [10 (0 to 46) vs 9 (0 to 36), p=0,03] and SDS [3 (0 to 35) vs 2 (0 to 34), p=0,03] were higher in T1 protocol. Global left ventricular ejection fraction did not differ between the two protocols, but motion and thickening scores were higher in T1 protocol. A highly significant (p < 0,001) linear relationship with clinically negligible mean differences in Bland-Altman analysis was observed for all perfusion and function-related data. Sensitivity was 80% for T1 and 78% for T2 protocol, specificity was 65% for both protocols, while diagnostic accuracy, as evaluated by AUC [0,75 (0,62-0,84 95% CIs) for T1 and 0,71 (0,58-0,81 95% CIs) for T2] was similar between the two protocols (p=0,3).CONCLUSIONS 25The fast protocol is technically feasible and diagnostically accurate compared to the established protocol.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2016
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Katsikis, Athanasios
- Κατσίκης, Αθανάσιος
Subjects
dc:subject × 6Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/38949