Back to search

National and Kapodistrian University of Athens

Ανάπτυξη αλγορίθμων και μεθόδων ποιοτικού ελέγχου για το δοσιμετρικό σχεδιασμό εφαρμογών βραχυθεραπείας

Abstract

dc:description

Recently, Model Based Dose Calculation Algorithms (MBDCAs) beyond TG-43 have been incorporated in Treatment Planning Systems (TPSs) for 192Ir High-Dose-Rate (HDR) brachytherapy. The complexity of these algorithms, however, introduces new quality assurance (QA) standards augmentιng current societal recommendations, while an effort is needed towards evaluating the clinical impact of the improved dosimetric accuracy that they obtain in specific treatment sites. To this end, a software tool (BrachyGuide) was developed for the automatic preparation of the Monte Carlo (MC) input files, which is considered the reference method for patient specific dosimetry. Subsequently, a user-oriented QA procedure was developed for two commercially available MBDCAs, based on computational dosimetry. The reference dose distributions were generated using MC simulation with input files prepared using BrachyGuide. The comparison of MC and MBDCA results was found in accordance with corresponding studies in the literature, while the data and tools presented are freely distributed via the web to facilitate the implementation of QA procedures for MBDCAs. In addition, an experimental-based QA procedure was developed using the novel TruView™ radiochromic gel with Optical Tomography. In the absence of relevant literature, the dose response of the TruView™ dosimeter was calibrated and evaluated to demonstrate its suitability for use in experimental commissioning tests in HDR brachytherapy, using MC simulation with BrachyGuide. The results demonstrated that TruView™ in conjunction with Optical Tomography, although not fully characterized yet, could be suitable for the implementation of QA procedures for MBDCAs in HDR brachytherapy. The dosimetric test performed for a TPS employing an MBDCA using TruView™ dosimeter and Optical Tomography showed that the MBDCA provides improved dosimetric accuracy relative to the TG-43 algorithm, in line with previously published data. Furthermore, treatment plan cohorts of breast, head and neck and lip patients treated with HDR brachytherapy were pooled. TG-43 data and corresponding MC calculations using BrachyGuide were compared for each patient. Results showed that the TG-43 algorithm presents a generally significant, yet small, dose overestimation relative to MC simulation for breast and head and neck patient cohorts. Although these differences may not be considered of major clinical significance in terms of plan acceptance criteria, improved dosimetric accuracy offered by MBDCAs could be useful in cases such as re-irradiation and comparison between different techniques for long-term toxicity determination, as well as for secondary cancer induction risk assessment. In terms of lip patients, considerable differences were found between TG-43 and MC-based dosimetry, which imply that the implementation of MBDCA dosimetry in HDR brachytherapy of the lip carcinoma may be of major clinical importance. However, adherence to clinical recommendations for patient selection and good implant quality, followed by optimization and image based planning, remain the decisive elements of treatment quality.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2016

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Peppa, Vasiliki
  • Πέππα, Βασιλική

Subjects

dc:subject × 10

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/38994

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Peppa, Vasiliki; Πέππα, Βασιλική. Ανάπτυξη αλγορίθμων και μεθόδων ποιοτικού ελέγχου για το δοσιμετρικό σχεδιασμό εφαρμογών βραχυθεραπείας. National and Kapodistrian University of Athens, 2016. http://hdl.handle.net/10442/hedi/38994