Back to search

University of Patras

A method for the accessment of the imaging properties of tomographic nuclear medicine systems (spect, pet) by using the line spread function (LSF)

Abstract

dc:description

The aim of our work was to provide a robust method for evaluating imaging performance of positron emission tomography (PET) systems and particularly to estimate the modulation transfer function (MTF) using the line spread function (LSF) method. A novel plane source was prepared using thin layer chromatography (TLC) of a fluorine-18-fluorodeoxyglucose (18F-FDG) solution. The source was placed within a phantom, and imaged using the whole body (WB) two dimensional (2D) and three dimensional (3D) standard imaging protocols in a GE Discovery ST hybrid PET/CT scanner. Modulation transfer function was evaluated by determining the LSF, for various reconstruction methods and filters. The proposed MTF measurement method was validated against the conventional method, based on point spread function (PSF). Higher MTF values were obtained with 3D scanning protocol and 3D iterative reconstruction algorithm. All MTF obtained using 3D reconstruction algorithms showed better preservation of higher frequencies than the 2D algorithms. They also exhibited better contrast and resolution. MTF derived from LSF were more precise compared with those obtained from PSF since their reproducibility was better in all cases, providing a mean standard deviation of 0.0043, in contrary to the PSF method which gave 0.0405. By using our novel plane source we developed a method for measuring the image registration shift between the CT and the PET images in fusion. The method gave results that are comparable to the manufacturers’ method for image registration and has the advance that is applicable to all scanner models. Through the MTF it is also feasible to compare commercially available scanners in terms of image quality. In conclusion, the proposed method is novel and easy to implement for characterization of the signal transfer properties and image quality of PET/CT systems. It provides an easy way to evaluate the frequency response of each kernel available. The proposed method requires cheap and easily accessible materials, available to the medical physicist in the nuclear medicine department. Furthermore, it is robust to aliasing and since this method is based on the LSF, is more resilient to noise due to greater data averaging than conventional PSF-integration techniques. In this study was used to assess the image quality. But it can also be used as a method of quality control and stability of system performance over time.

Degree

thesis:*
Grantor dc:publisher
University of Patras
Year dc:date
2014

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Samartzis, Alexandros
  • Σαμαρτζής, Αλέξανδρος

Subjects

dc:subject × 20

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/39189

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Samartzis, Alexandros; Σαμαρτζής, Αλέξανδρος. A method for the accessment of the imaging properties of tomographic nuclear medicine systems (spect, pet) by using the line spread function (LSF). University of Patras, 2014. http://hdl.handle.net/10442/hedi/39189