National Technical University of Athens (NTUA)
Συμβολή στη μελέτη της αντικεραυνικής προστασίας πλοίου
Abstract
dc:descriptionWith the extended electrification of all onboard systems and the use of vital electronic equipment lightning arises as a serious danger for ships. In the present dissertation the physical procedures of the interaction between lightning and the hull of a ship are at first analyzed along with the relative performed research and the requirements of the regulations. Overestimation of the resulting protection zone on a complex ship geometry was concluded by comparing results from impulse voltage experiments on a scaled down ship model to the calculations of lightning protection zone models. Lightning interception probability and proximity effects were highlighted as dominant factors. The needs of an impulse current injection experiment on a scaled down ship model are investigated through measurements on grounding electrodes placed in an electrolytic tank with application of the Similarity Theory and Dimensional Analysis. According to lightning incidence calculations on various ship models, a lightning strike is expected on a ship approximately every two or three years on coastal areas with intense lightning activity. Meanwhile, a thorough procedure was developed for the execution of lightning shielding analysis on the masts of a ship incorporating the statistical nature of lightning. Apart from the external lightning protection system, the need for internal lightning protection with the installation of surge protective devices was outlined through electromagnetic simulations of various lightning strike scenarios on a 3d ship geometry with embedded basic routes of cable harness. The calculated induced overvoltages in the ship electric network might even reach during a subsequent lighting strike 2kV for indoor cables close to openings or 5kV for exposed outdoor cables and they are coupled to distances deep below the deck. Therefore, the further investigation of the immunity requirements for marine equipment according to IEC 60945 and IEC 60533 and their possible reassessment to higher surge immunity levels is proposed.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2016
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Nicolopoulou, Eleni
- Νικολοπούλου, Ελένη
Subjects
dc:subject × 22- Κεραυνοπληξία πλοίου
- Αντικεραυνική προστασία
- Πειράματα κλίμακας
- Θεωρία της Ομοιότητας
- Πιθανότητα σύλληψης
- Ανάλυση θωράκισης
- Φαινόμενα γειτνίασης
- Επαγόμενες υπερτάσεις
- Ηλεκτρομαγνητική ατρωσία
- Lightning strikes on ships
- Lightning protection
- Scaled-down experiments
- Similarity Theory
- Interception probability
- Proximity effects
- Shielding analysis
- Lightning induced effects
- Electromagnetic immunity
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ
- Engineering and Technology
- Electrical Engineering, Electronic Engineering, Information Engineering
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/39195