National Technical University of Athens (NTUA)
Συμβολή στην ανάπτυξη ολοκληρωμένης μεθοδολογίας εκτίμησης εκπομπών αρμονικών από ανεμογεννήτριες
Abstract
dc:descriptionΤhe state of the art in the calculation of wind turbine (WT) harmonic emissions, according to IEC Standard 61400-21, is based on the requirements of IEC 61000-4-7, which covers harmonic measurement and assessment in all power supply systems. The fundamental approach of IEC 61000-4-7 consists in the application of the Fast Fourier Transform (FFT) with specific assumptions for the window type and duration reflecting a compromise between accuracy and computational burden. To cope with spectral leakage due to imperfect frequency resolution of the FFT and the non-stationarity of the examined signals, the Standard recommends the use of Phase Locked Loop (PLL) devices in the measurement stage and the application of the methodology of “grouping” in the assessment stage.Although IEC 61000-4-7 is adopted by all measuring institutes involved in PQ certification of commercial WTs, several aspects are still open to further investigation. This Phd Thesis deals with evaluation of the current methodology of the measurement and assessment of WT harmonics according to IEC 61400-21 and IEC 61000-4-7 standards, based on field measurements, and the study and application of alternative harmonic analysis methodologies more suitable for non-stationary signals. As part of the study, harmonic emissions of a wind farm (WF) are also investigated, aiming at the identification of contribution of individual harmonic sources (i.e. WTs) to the formation of the aggregate wind farm current, for the discussion of the basic hypotheses of IEC 61000-3-6.The thesis begins with the study of the most significant harmonic analysis methods, in terms of WT current and voltage processing. Then, the FFT-based grouping methodology, introduced by the IEC 61000-4-7, is presented and discussed. Based on field measurements, a thorough investigation of WT harmonic emissions is performed, including the effect of the WT operating point and the selection of calculation parameters. The examined WTs represent a variety of configurations regarding the electrical system and important results are drawn concerning the spectral characteristics and the statistical behavior of harmonic currents, applying the IEC 61000-4-7 methodology. Next, the Wavelet Transform, the Hilbert-Huang Transform and Prony methods are applied, first to selected synthetic signals and then to real WT signals, in order to evaluate their suitability and identify particular advantages, drawbacks and limitations in their applicability in the assessment of WT harmonics. Finally, the analysis of real WF measurements is included, from which useful conclusions are drawn about the contribution of single WTs to the total harmonic current emissions of wind installations.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2014
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Tentzerakis, Sokratis
- Τεντζεράκης, Σωκράτης
Subjects
dc:subject × 27- Ανεμογεννήτριες
- Αιολικά πάρκα
- Αρμονικές ρεύματος και τάσης
- Μετρήσεις αρμονικών
- Πρότυπα IEC
- IEC 61400-21
- IEC 61000-4-7
- Μετασχηματισμός Fourier
- Μετασχηματισμός wavelets
- Μέθοδος hilbert-huang
- Μέθοδος prony
- Συστήματα ηλεκτρικής ενέργειας
- Wind turbines
- Wind farms
- Current and voltage harmonics
- Power quality
- Harmonic measurements
- Harmonic limits
- Fourier transform
- Wavelet transform
- Hilbert-Huang transform
- Prony method
- Electric power systems
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ
- Engineering and Technology
- Electrical Engineering, Electronic Engineering, Information Engineering
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/39460