Back to search

National Technical University of Athens (NTUA)

Τεχνικές εκτίμησης και επιλογής συγχρονισμένων μετρήσεων φασιθετών σε συστήματα ηλεκτρικής ενέργειας

Abstract

dc:description

The last decades, electric power industry is undergoing multiple changes due to the process of deregulation. Nowadays, the competitive electricity markets provide efficient power generation, technological innovations, and eventually lower retail prices. In this environment, secure operation of power systems requires close monitoring of the system operating conditions. This is accomplished through control centres, gathering the data received from numerous substations to provide an estimate of the bus voltage phasors, the tap positions, the circuit breaker status, and other metered and unmetered electrical quantities and parameters of the power system. Traditionally, the available data are redundant measurements commonly provided by SCADA, including active and reactive power flows and injections and bus voltage magnitudes and statuses of switching devices. With the advent of global positioning system (GPS), the measurement set is enlarged to include the available synchronized phasor measurements provided by the phasor measurement units (PMUs). These are measurement devices providing the precise knowledge necessary to minimize and control power outages and avoid problems such as cascading blackouts. This dissertation is focused on the possible benefits of using synchronized phasor measurements and PMUs in order to improve the power system monitoring and control. The benefits are investigated with respect to the measurement system observability analysis, the optimal PMU placement, and the power system state estimation. Initially, this dissertation presents simple and effective algorithms concerning the observability analysis, checking and restoration, for systems including phasor measurement units as well as conventional measurements. Novel methods of optimal PMU placement based on heuristic and mathematical algorithms ensuring maximum measurement redundancy and considering or not conventional measurements, are also proposed. Finally, weighted least square formulations of the state estimation problem, including traditional as well as voltage and current phasor measurements are presented. The proposed formulations process simultaneously or not the different measurement types and avoid any numerical problems encountered by using the polar or rectangular coordinates of current phasors. The results show that the strategic placement of a few PMUs in the system can significantly increase measurement redundancy, which in turn can improve the capability of bad data detection and identification.

Degree

thesis:*
Grantor dc:publisher
National Technical University of Athens (NTUA)
Year dc:date
2013

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Manousakis, Nikolaos
  • Μανουσάκης, Νικόλαος

Subjects

dc:subject × 23

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/39563

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Manousakis, Nikolaos; Μανουσάκης, Νικόλαος. Τεχνικές εκτίμησης και επιλογής συγχρονισμένων μετρήσεων φασιθετών σε συστήματα ηλεκτρικής ενέργειας. National Technical University of Athens (NTUA), 2013. http://hdl.handle.net/10442/hedi/39563