National Technical University of Athens (NTUA)
Τεχνικές εκτίμησης και επιλογής συγχρονισμένων μετρήσεων φασιθετών σε συστήματα ηλεκτρικής ενέργειας
Abstract
dc:descriptionThe last decades, electric power industry is undergoing multiple changes due to the process of deregulation. Nowadays, the competitive electricity markets provide efficient power generation, technological innovations, and eventually lower retail prices. In this environment, secure operation of power systems requires close monitoring of the system operating conditions. This is accomplished through control centres, gathering the data received from numerous substations to provide an estimate of the bus voltage phasors, the tap positions, the circuit breaker status, and other metered and unmetered electrical quantities and parameters of the power system. Traditionally, the available data are redundant measurements commonly provided by SCADA, including active and reactive power flows and injections and bus voltage magnitudes and statuses of switching devices. With the advent of global positioning system (GPS), the measurement set is enlarged to include the available synchronized phasor measurements provided by the phasor measurement units (PMUs). These are measurement devices providing the precise knowledge necessary to minimize and control power outages and avoid problems such as cascading blackouts. This dissertation is focused on the possible benefits of using synchronized phasor measurements and PMUs in order to improve the power system monitoring and control. The benefits are investigated with respect to the measurement system observability analysis, the optimal PMU placement, and the power system state estimation. Initially, this dissertation presents simple and effective algorithms concerning the observability analysis, checking and restoration, for systems including phasor measurement units as well as conventional measurements. Novel methods of optimal PMU placement based on heuristic and mathematical algorithms ensuring maximum measurement redundancy and considering or not conventional measurements, are also proposed. Finally, weighted least square formulations of the state estimation problem, including traditional as well as voltage and current phasor measurements are presented. The proposed formulations process simultaneously or not the different measurement types and avoid any numerical problems encountered by using the polar or rectangular coordinates of current phasors. The results show that the strategic placement of a few PMUs in the system can significantly increase measurement redundancy, which in turn can improve the capability of bad data detection and identification.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2013
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Manousakis, Nikolaos
- Μανουσάκης, Νικόλαος
Subjects
dc:subject × 23- Επεξεργασία εσφαλμένων δεδομένων
- Συμβατικές μετρήσεις
- Ευρετικοί αλγόριθμοι
- Μαθηματικοί αλγόριθμοι
- Ανάλυση παρατηρησιμότητας
- Πρόβλημα βέλτιστης τοποθέτησης μονάδων PMU
- Μονάδες μέτρησης φασιθετών (PMU)
- Συγχρονισμένες μετρήσεις
- Εκτίμηση κατάστασης
- WLS
- Bad data processing
- Conventional measurements
- Mathematical algorithms
- Heuristic algorithms
- Observability analysis
- Optimal PMU placement problem
- Phasor measurement unit (PMU)
- Synchronized measurements
- State estimation
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ
- Engineering and Technology
- Electrical Engineering, Electronic Engineering, Information Engineering