Back to search

National and Kapodistrian University of Athens

Ενδαρτηριακή θεραπευτική προσέγγιση ηπατικών, νευροενδοκρινούς χαρακτήρα, νεοπλασιών με 111Iνδιο-πεντετριοτίδιο μετά από προσωρινή εγκατάσταση καθετήρα (port)

Abstract

dc:description

Purpose: To evaluate the effectiveness of high doses of 111Ιn-DTPA‐OCinfusions following selective catheterization of the hepatic artery throughout atemporary port installation in inoperable liver metastasized, SSTR2 positive neuroendocrinetumours due to the effect of 111Ιn Auger and Internal Conversion ElectronEmission.Materials and Methods: The average dose per session administeredmonthly to each patient (9 cases in total) was 6.3±2.3 GBq. Since repeatitions raisedthe 12 fold in order to exempt patients from the repeated catheterizationprocedure discomfort, a temporary intraarterial installation of a specificcatheterization port system was performed. Response assessment was classifiedaccording to the Response Evaluating Criteria In Solid Tumours (RECIST). CT/MRIscans were performed as baseline before, during and after the end of treatment andmonthly US images for follow up measurements. Toxicity (WHO criteria) wasmeasured using blood and urine tests of renal, hepatic and bone marrow function.Results: No one from the treated patients [108 infusions] achieved completeresponse [CR: 0.0%] , partial response [PR] was observed in 7 (70 %) and diseasestabilization[SD] in 2 ( 30 %) patients. Dosimetric calculations showed an about 75%(p<0.05) higher radiopeptide cumulative dose compared to that of the simpleintravenous administration. Grade 1 erythro-, leuko- and thrombo- cytopeniaoccurred in 3 (34.0 %) cases.Conclusion: In unresectable metastatic liver lesions, positive for somatostatinreceptors repeated, trans‐hepatic, high doses of 111Ιn-DTPA‐OC throughout atemporary port installation, showed an effective therapeutic outcome. Given thelocoregional modality character of the administration technique after the temporaryport installation for the completion of the treatment plus the extremely short range of111Ιn Auger and Internal Conversion electrons emission, no nephro-, liver- or myelotoxicityhas so far been observed. The implantable port system offers stable connection mechanism at port chamber/catheter junction, high flow rate in thincatheters, secure placement of the puncture needle in the chamber septum, easylocation of the puncture site and quality of life.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2016

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Karfis, Ioannis
  • Καρφής, Ιωάννης

Subjects

dc:subject × 11

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/39579

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Karfis, Ioannis; Καρφής, Ιωάννης. Ενδαρτηριακή θεραπευτική προσέγγιση ηπατικών, νευροενδοκρινούς χαρακτήρα, νεοπλασιών με 111Iνδιο-πεντετριοτίδιο μετά από προσωρινή εγκατάσταση καθετήρα (port). National and Kapodistrian University of Athens, 2016. http://hdl.handle.net/10442/hedi/39579