Διερεύνηση της πιθανής επίδρασης της τοποθέτησης συσκευής σύγκλισης Amplatzer σε ασθενείς με ανοιχτό ωοειδές τρήμα στη λειτουργικότητα των κόλπων και την ενεργοποίηση των δεικτών πηκτικότητας και αιμοπεταλιακής ενεργοποίησης

Abstract

dc:description

Background: Evaluation of left atrial (LA) size and function using conventional and more recent echocardiographic parameters is potentially feasible in the routine clinical setting. However the influence of the Amplatzer septal occluder (AGA Medical Corp, Golden Valley, Minn) in the left atrium function after percutaneous closure of patent foramen ovale (PFO) under intracardiac echo guidance has not been thoroughly studied.Methods: Over a period of 40 months, 50 patients (pts) with PFO were referred to our center for clinically indicated percutaneous PFO closure. Among them 25 pts (mean age 40.7±12 years) were enrolled in our study due to cerebovascular events and transient ischemic attacks. Transthoracic echocardiogram (TTE) was performed in all pts before the procedure, at 3 and 6 months after the intervention. Phasic LA volumes were measured and volumetric indices were derived accordingly. Strain and strain rate were calculated in all 25 pts for the lateral, anterior and inferior LA walls. Peak strain and strain rate values were measured during the contractile, reservoir and conduit LA phases. A transesophageal echogram (TEE) was also undertaken at the 6-month follow-up to verify complete closure of the defect.Results: All patients completed the procedure uneventfully and at 6-month follow-up the closure appeared intact. For the LA lateral wall, the total 3 values were correlated with the LA volumetric indicators (LA active emptying fraction: LA AEF, LA expansion index: LAEI, and LA passive emptying fraction: LA PEF). After 3 months a decrease in the strain rate of the anterior wall of LA was observed (from 2.12±0.22 to 1.66±0.26, p=0.045), while LA AEF was greater compared to baseline (from 31.0±1.6 to 34.0±1.6, p=0.004). Conclusions: Closure of patent foramen ovale with the Amplatzer PFO occluder results in altered LA function. Strain and strain rate represent a promising tool in the evaluation and follow-up of patients who have undergone PFO closure

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2015

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Kavvouras, Charalampos
  • Κάββουρας, Χαράλαμπος

Subjects

dc:subject × 17

Rights

dc:rights
Statement dc:rights
  • BY_NC_SA
Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/39738

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Kavvouras, Charalampos; Κάββουρας, Χαράλαμπος. Διερεύνηση της πιθανής επίδρασης της τοποθέτησης συσκευής σύγκλισης Amplatzer σε ασθενείς με ανοιχτό ωοειδές τρήμα στη λειτουργικότητα των κόλπων και την ενεργοποίηση των δεικτών πηκτικότητας και αιμοπεταλιακής ενεργοποίησης. National and Kapodistrian University of Athens, 2015. http://hdl.handle.net/10442/hedi/39738