National and Kapodistrian University of Athens
Biomechanics analysis of motion-gait in patients subjected in two different types of total knee arthroplasty 1. Medial Pivot and 2. Rotating platform posterior stabilized with posterior cruciate ligament sacrifice: kinetics data comparison 2 to 3 years postoperatively
Abstract
dc:descriptionIn physics the magnitude of forces, moments and ranges of motion are fundamental inputs for the biomechanical study of motion and gait in patients subjected to total knee arthroplasty (TKA). The detailed examination of kinetic and kinematic parameters the gait cycle is divided to primarily to eight phases. Five phases correspond to stance phase while three phases correspond to swing phase. Every time instant during gait, the human joints are subjected to particular moment in particular ranges of motion. Thus the normal gait pattern is created.Any deviation from the normal gait pattern constitutes pathological gait of specific etiology and pathology. Typical example is the gait pattern of patients suffers from knee osteoarthritis. Depending on the stage of disease they show reduced velocity, cadence and stride length. The phases of single and double support are increased compared to the swing phase. The maximum range knee extension and flexion of motion is reduced as well as the maximum knee adduction and extension moment respectively.Another typical example of pathological gait is the pattern of patients subjected to total knee arthroplasty. Many studies concluded that the subjects walk with a substantial deviation compared to the normal values of normal parameters. Two recent studies summarize the characteristics of their gait pattern primarily to reduced velocity and stride length as well as to reduced single support phase. The kinetic parameters at the sagittal plane show reduced maximum knee extension and flexion moment during support phase. It is worth to mention that different types of TKA’s show deviations to these parameters.The study of arthrokinematics of the normal knee joint is important for the development of total knee implant designs. Biomechanists try to imitate the normal flexion and extension, anteroposterior translation as well as the rest of the motion in axial and frontal plane in TKA implants. They intend always to deal with the issues of the implant functionality, longevity and wear.Studies to these direction developed two types of TKA’s that show good results to the above paremeters: the medial pivot and the rotating platform posterior stabilized implants.Each of these designs show particular kinematic characteristics so as to compensate to many factor that could cause failure of the arthroplasty. One such main factor is the wear of the polyethylene insert. Most of the researchers try to approach wear by studying primarily the sagittal and secondly the frontal plane biomechanics. Nevertheless transverse plane biomechanics are equally important for the study of wear even if the main motion does not occur at this plane. Moreover the International Standardization Organization suggests the study of range of motion and forces (and as a result moments) in all three planes important for the study of wear.The research of this PhD thesis concentrated to the study of the knee moment and overall range of motion in transverse plane of patients subjected in two different types of total knee arthroplasty: the medial pivot and the rotating platform posterior stabilized implants. For the measurement of the parameters there was used eight optoelectronic cameras and two force plates at the biomechanics laboratory “Sylvia Ioannou” of the 1st department of Orthopaidics, N.K.U.A. the aim of the study was to examine the rotational behavior of these TKA’s and their effect on polyethylene wear.In this study no statistical significant differences were found between two groups at the examined parameters. Both implants show similar biomechanical behavior during gait. Nevertheless kinematic gait pattern differences were observed between two groups. These differences may reflect the different pattern of motion of the two implant designs. Several studies maintain that even small differences of transverse plane range of motion could have substantial effect on polyethylene wear. Thus our results should combined with several input waveforms as well as functional gait analysis at the transverse plane so as to identify the actual effect of gait on TKA wear.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2017
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Papagiannis, Georgios
- Παπαγιάννης, Γεώργιος
Subjects
dc:subject × 8Rights
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/40084