National Technical University of Athens (NTUA)
Ανάπτυξη χημικών αισθητήρων για την ανίχνευση τοξικών ουσιών
Abstract
dc:descriptionThe present dissertation was focused on the topic of chemical sensors for rapid detection of toxic substances, an investigation that was made for first time in the literature. For this purpose, biosensors using printed circuits composed from graphene microelectrodes using stabilized lipid membranes were constructed and developed.A number of particular methodologies were used to embody various receptors such as enzymes (urease and cholesterol oxidase) and an antibody (antibody D-dimer) in the sensors.Various physicochemical and instrumental methods of analysis, eg., differential scanning calorimetry (DSC), scanning electron microscopy (SEM), Raman spectrophotometry, etc., were used to locate the position of the receptor (eg. antibody, enzyme, etc.) into the stabilized lipid membrane of the sensor and the mechanism of signal generation.The response of the sensor to various potentially toxic substrates eg. urea (urease immobilization), cholesterol (cholesterol oxidase immobilization) and D-dimer (immobilizing antibody D-dimer) and its stability with time were studied.For example, the response of urea biosensor towards various urea concentrations was found to have high sensitivity (ca. 70 mV/ concentration decade) over a range of urea concentrations between 1 Χ 10−6 Μ - 1 Χ 10−3 Μ. The response of cholesterol biosensor towards various concentrations of the substrate were also found to be highly sensitive (ca. 64 mV/ concentration decade) over a concentration range between 1 Χ 10−6 Μ - 1 Χ 10−3 Μ; this sensitivity is larger than those provided up to date in the literature. Finally the response of the D-dimer immunosensor was found satisfactory over a wide concentration range of analyte (10-6 μg/ mL - 10-3 μg/ mL) with a sensitivity of ca. 59 mV/ concentration decade with a rapid response of 15 s.The selectivity of the sensor construction method and on how to limit interferences were studied so that the sensor could be applied in real samples. The conditions for satisfactory stability and reproducibility of the chemical sensors were thoroughly studied and their construction into nanoscale was investigated.The results of the implementation of the constructed devices in real samples were satisfactory and show the possibility of construction of portable chemical sensors for the detection of toxicants for first time in the literature with many advantages, which can be used in the future as alternative systems instead of the time consuming, costly and complex chromatographic methods of analysis.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2015
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Nikoleli, Georgia-Paraskevi
- Νικολέλη, Γεωργία-Παρασκευή
Subjects
dc:subject × 18- Αναλυτική χημεία
- Χημικοί αισθητήρες
- Ηλεκτρόδιο γραφενίου
- Ουρία
- Χοληστερόλη
- D-dimer
- Stabilized lipid membranes
- Electroanalysis
- Biosensors
- Graphene nanosheets
- Φυσικές Επιστήμες
- Χημεία
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Χημικού Μηχανικού
- Natural Sciences
- Chemical Sciences
- Engineering and Technology
- Chemical Engineering
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/40089