National and Kapodistrian University of Athens
Συγκριτική μελέτη της μορφομετρίας κατά τον κλασικό ακτινολογικό έλεγχο (MRX) και της μορφομετρίας με χρήση απορροφησιομετρίας (VFA) στον καθορισμό σπονδυλικών παραμορφώσεων σε οστεοπορωτικούς ασθενείς μετά από κυφοπλαστική
Abstract
dc:descriptionObjective: To apply, for the first time internationally, the method of Vertebral Fracture Assessment (VFA) to patients treated with kyphoplasty for osteoporotic vertebral fractures. To analyze the advantages and disadvantages of VFA, check its reliability and compare VFA with morphometric x-ray absorptiometry (MRX) in the assessment of vertebral deformities to the particular patients.Patients and Methods: Forty-two patients treated with kyphoplasty underwent VFA and MRX. Anterior (ha), middle (hm) and posterior (hp) heights of the vertebral bodies were measured and the ratios ha/hp and hm/hp were calculated. Initially, we estimated the intraobserver agreement (IOA) and the interobserver agreement (INA) for the VFA using ha/hp and hm/hp ratios as well as the Genant method. The relative intra-class correlation coefficient (ICC) was calculated on the “vertebral” level, on the “region” level (thoracic or lumbar), on the “vertebrae with kyphoplasty” level and on the “adjacent to the kyphoplasty vertebrae” level using the mean value of ha/hp and hm/hm on each level. Then, we analyzed the agreement between VFA and MRX on measuring ha/hm and hm/hp ratios and after the ratio ha/hp was dichotomized above or below cut-off levels that are commonly used to identify fractures. Results: Intra- and interobserver agreement for the ratios ha/hp and hm/hp on VFA was “almost perfect” on all levels (ICC 0.94-0.98). Application of the Genant’s cut-off ratios for assessing the vertebrae during VFA also showed “almost perfect” interobserver agreement (κ = 0.833). Analysis on a “vertebral” level resulted in “almost perfect” agreement between VFA and MRX using the ratio ha/hp (ICC=0.85) and in “strong agreement” using the ratio hm/hp (ICC=0.78). Using the ratio ha/hp agreement was “almost perfect” on the thoracic (ICC=O.82) and lumbar region (ICC=0.87) while for the ratio hm/hp agreement was “strong” on the thoracic (ICC=0.75) and “almost perfect” on the lumbar region (ICC=0.80) of the spine. Agreement was also “almost perfect on the “vertebrae with kyphoplasty” level (ICC=0.83) as well as on the “adjacent to the kyphoplasty vertebrae” level (ICC=0.80) for the ratio ha/hp. If the ratios ha/hp were translated into fractures (yes vs no) using different cut off levels for a fracture (AP-ratios 0.75, 0.80 or 0.85) between-method agreement became moderate to substantial (κ 0.52-0.63 on the lumbar and 0.53-0.66 on the thoracic spine). Differences using the Genant classification were mostly in the direction of MRX with 32 identified fractures only on MRX and 5 only in VFA. In this study with a prevalence of 9.3% of vertebral fractures, the sensitivity, specificity, positive predictive value (PPV) και negative predictive value (NPV) were 0.522, 0.97, 0.87 και 0.92 respectively. Conclusion: Application of VFA to patients with kyphoplasty has high repeatability and reproducibility. Agreement between VFA and MRX on assessing vertebral deformities using the ratios ha/hp and hm/hp was “strong” to “almost perfect” depending on the level examined. Beyond the agreement between VFA and MRX in assessing vertebral deformities, expressed as ha/hp and hm/hp ratios, applying the Genant method resulted in less agreement between methods. Differences were mostly on the direction of MRX and this is in line with the literature reporting smaller sensitivity and specificity of the VFA using the Genant method in identifying mild vertebral fractures in comparison to the MRX. The high value, though, of NPV for the VFA on patients with kyphoplasty indicates that the method could be used to select patients for further evaluation by X-ray when assessing vertebral fractures as a sign of bone failure.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2017
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Drampalos, Efstathios
- Δράμπαλος, Ευστάθιος
Subjects
dc:subject × 16- Μορφομετρία με χρήση απορροφησιομετρίας (VFA)
- Μορφομετρία κατά τον ακτινολογικό έλεγχο (MRX)
- Σπονδυλικές παραμορφώσεις
- Οστεοπόρωση
- Κυφοπλαστική
- Συγκριτική μελέτη
- Vertebral Fracture Assessment (VFA)
- Morphometric X-ray Absorptiometry (MRX)
- Vertebral deformities
- Osteoporosis
- Kyphoplasty
- Comparative study
- Ιατρική και Επιστήμες Υγείας
- Κλινική Ιατρική
- Medical and Health Sciences
- Clinical Medicine
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/40405