Παράγοντες που επηρεάζουν τη φθορά του πολυαιθυλενίου της κοτυλιαίας πρόθεσης στις ολικές αρθροπλαστικές του ισχίου
Abstract
dc:descriptionPolyethylene wear in vivo is a multifactorial process influenced by many variables. This could explain the large variations in polyethylene wear rates among patients with total hip arthroplasty (THA).In this prospective study, we analyzed data from 200 THA performed between 1990 and 1998 in order to determine the influence of patient, surgical technique and implant related factors on the polyethylene wear rate. In addition, we assessed the effect of the increased polyethylene wear rate on revision rate, aseptic loosening and periprosthetic osteolysis and we evaluated variations in polyethylene wear rates during time.The polyethylene wear rate was significantly greater in younger, non-obese patients, with increased activity level and with avascular necrosis of the femoral head. Vertical and lateral placement of the acetabular component, partial bony coverage of the cemented all polyethylene acetabular component, valgus placement of the femoral component, proximal reattachment of the greater trochanter and proximal migration of wire fragments, produced after breakage of the wires used for the reattachment of the greater trochanter, were statistically significantly related to increased polyethylene wear rate. The Trendelenburg sing preoperatively and postoperatively, the change of leg length over 2cm and the postoperative dislocation led to a statistically significant increase in polyethylene wear rate. Cementless metal-back acetabular component, conventional polyethylene sterilized with ethylene oxide and modular femoral component were also associated with statistically significantly higher polyethylene wear rate. Multiple linear regression analysis revealed that polyethylene wear rate was significantly correlated only with patient’s activity level, lateral positioning of the acetabular component and valgus placement of the femoral component and that those factors accounted for 53.3% of the variance in polyethylene wear rates. Multiple logistical regression analysis showed that increased polyethylene wear rate significantly affected acetabular or/and femoral component revision rate, aseptic loosening of acetabular or/and femoral component, periacetabular linear and expansile osteolysis, expansile osteolysis around femoral component as well as linear or/and expansile osteolysis in Gruen VII zone of the femoral component. Repeated measures ANOVA (RMANOVA) analysis showed statistically significant difference of polyethylene wear rate at 5 years from the initial operation, at 10 years and at the latest follow-up, after 10 years. In addition, it revealed statistically significant differences in variation of the polyethylene wear rate during time between cemented all polyethylene and cementless metal backed acetabular components and between conventional polyethylene sterilized with gamma irradiation on air and conventional polyethylene sterilized with ethylene oxide.The above factors influencing polyethylene wear rate in vivo should be taken into account for the avoidance of technical mistakes during surgery, the selection of the optimum prosthesis for each patient and the determination of patients in danger for increase polyethylene wear rate who need frequent examination in order to prevent extensive osteolysis which will make the revision surgery more complicated. Although cross linked polyethylene and hard on hard bearings reduced wear in THA, the wear in a complex biological – mechanical system such as THA could not be eliminated and many of the above factors were expected to influence it in those new bearings surfaces as well.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2013
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Georgiades, Georgios
- Γεωργιάδης, Γεώργιος
Subjects
dc:subject × 10Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/40441