Back to search

National Technical University of Athens (NTUA)

Σχεδίαση συστημάτων ανίχνευσης αστάθειας τάσεως και προστασίας από κατάρρευση

Abstract

dc:description

The scope of this thesis is the design and development of on-line voltage instability detection systems and protection schemes against voltage collapse.For this purpose, the Local Identification of Voltage Emergency Situations (LIVES) method is utilized. This method relies on monitoring of secondary controlled voltage of bulk power delivery transformers equipped with Load Tap Changer (LTC) in order to detect instability. LIVES is incorporated in a simple detection system which can be used either for stability monitoring only, or as a part of a System Protection Scheme (SPS) against voltage collapse. All SPS designed in the framework of this thesis are local, closed-loop systems.The first SPS designed is based in emergency tap control, after the detection of instability and up to the point where stability is restored. The emergency control is based on the reverse operation of LTC in favor of transmission voltage. Furthermore, this SPS is equipped with a module for restoring LTC control range in case a hard tap limit is reached and thus restoring the operability of the SPS, which is based on active LTCs.The second SPS is a variation of the previous one, with the additional function of direct load shedding from the respective substation when an instability alarm is issued and the transmission or the distribution side voltage is below predefined thresholds. The direct load shedding is inevitable in case the loads are self-restored with dynamics other than LTCs.The third SPS applies a pre-specified percentage of firm load shedding from the distribution substation where the instability is detected by the LIVES detection system. The LIVES method is then extended into a New LIVES Index (NLI), suitable for any transmission bus feeding a weak area, regardless if the bus is controlled by LTC or not. The NLI can be easily computed using voltage and current phasor measurements from PMUs. All detection and protection schemes are modeled and incorporated into the WPSTAB software package, suitable for long term simulation and voltage stability analysis. WPSTAB is then used for simulation of all the detection and protection schemes in various test systems as well as, in the Hellenic Interconnected System.The main test system used is the IEEE Nordic Test System, proposed for voltage stability studies by the relevant IEEE Task Force. Also, stable and unstable scenarios from the Hellenic Interconnected System where used, based on the historical data from July 12, 2004 blackout, as well as from the summer of 2010. In the latter case, a study is carried out to determine the improvement of system security margins by using dispersed and centralized static compensation in the wind farms of Peloponnese and Megalopoli thermal plant respectively.

Degree

thesis:*
Grantor dc:publisher
National Technical University of Athens (NTUA)
Year dc:date
2017

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Lamprou, Charalampos
  • Λάμπρου, Χαράλαμπος

Subjects

dc:subject × 24

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/40457

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Lamprou, Charalampos; Λάμπρου, Χαράλαμπος. Σχεδίαση συστημάτων ανίχνευσης αστάθειας τάσεως και προστασίας από κατάρρευση. National Technical University of Athens (NTUA), 2017. http://hdl.handle.net/10442/hedi/40457