Democritus University of Thrace (DUTH)
Πειραματική μελέτη απομάκρυνσης ειδικών ρύπων σε πιλοτικές μονάδες τεχνητών υγροβιοτόπων
Abstract
dc:descriptionFor the conduction of the current doctoral dissertation eight pilot-scale constructed wetlands of two types (horizontal and vertical flow) operated treating university campus wastewater (Xanthi), wastewater enriched with chromium and agricultural wastewater. In specific, 5 horizontal subsurface flow CWs and 3 vertical flow CWs were used. From the HSF-CWs, three units contained medium gravel (MG-R, MG-C, MG-Z) and the other two contained one fine gravel (FG-R) and one cobbles (CO-R). The three units with medium gravel were planted one with common reeds (MG-R) and one with cattails (MG-C), and one was kept unplanted (MG-Z). The other two units were planted with common reeds (FG-R, CO-R). The stratification of the VF-CWs included (from bottom to top): cobbles, medium gravel, fine gravel and sand. One unit was planted with common reeds (W1), one with cattails (W2), while one was left unplanted (W3). During the operation at HSF-CWs four HRTs were applied (6, 8, 14 and 20 days), while at VF-CWs three loading/resting schedules were applied (2 days of feeding, followed by 4, 6 and 8 days of resting). The doctoral dissertation focused on the following pollutants:1.Common pollutants (Organic matter (BOD5, COD), Nitrogen (NH4-N, NΟ2-N, NΟ3-N, TKN), Phosporus (ΤΡ, ΟΡ), Total suspended solids (TSS), Total coliforms (TC)), 2.Endocrine Disrupting Chemicals ((EDCs) Νonylphenol (NP), NP1EO, NP2EO, Βisphenol A (BPA), Triclosan (TCS)), 3. Fungicide Boscalid, 4.Chromium (total and dissolved)Common Pollutants: The objective of this experimental part was the evaluation of the overall performance of the pilot-scale CWs, both horizontal (MG-R, MG-C, MG-Z) and vertical flow (W1, W2, W3) regarding the removal of these pollutants and the influence of several design and operation conditions such as: temperature and seasonal variation, presence and type of vegetation, feeding strategy (HRT for HSF-Ws and parallel cells for VF-CWs). The results were also compared with those from previous studies that were conducted on the same pilot-scale units and under similar conditions (hydraulic and climatic), where synthetic wastewater was used. The produced results indicated a good overall performance of the pilot-scale CWs. The performance was influenced by the vegetation, temperature (seasonal variation) and the feeding schedule. The planted units produced better results in comparison to the unplanted units, while all the units operated optimally during warmer months. In the HSF-CWs the removals were noted higher in the previous study (syntetic wastewater) regarding organic matter, while for the rest pollutants, the removals were higher in the present study in most cases and especially in the planted untis. In the VF-CWs the overall performance was better in the previous study (synthetic wastewater) in comparison to the present one. Finally, the results of the present study highlighted their long-term sustainable operation but also their high treatment capacity, since they have been in operation many years. Endocrine Disrupting Chemicals: The current experimental part targeted to the investigation of the removal of 5 EDCs present in municipal wastewater with the use of an alternative and environmental friendly technology, the CWs, both HSF (MG-R, MG-C, MG-Z) and VF (W1, W2, W3). The investegated substances were: Bisphenol A (BPA), Nonylphenol (NP), Nonylphenol monoethoxylate (NP1EO), Nonylphenol diethoxylate (NP2EO) and Triclosan (TCS). Results showed that the median removal performance in MG-R was 49.6%, 51.4% and 48.4%, in MG-C was 50.0%, 99.0% and 66.0%, and in MG-Z was 55.4%, 98.9% and 80.3% for BPA, NP1EO and NP2EO, respectively. NP was not removed but its concentration increased by 48.0%, 43.7% and 51.9% in the MG-R, MG-C and MG-Z, respectively. TCS was not detected in influent wastewater. In the VF-CWs, the median removal efficiencies were: 45.6%, -12.5%, 41.5% and 72.2% in W1, 60.0%, 96.2%, 99.0% and 99.8% in W2, and 59.0%, 95.6%, 98.7% and 99.8% in W3 for BPA, NP, NP1EO, NP2EO, respectively. The study indicates that the main removal pathways of the target EDCs is their biodegradation under aerobic or/and anaerobic conditions and adsorption onto the organic matter retained in the substrate.Fungicide Boscalid: The specific part focused on the investigation of the HSF-CWs (FG-R, CO-R) performance regarding the treatment of agricultural equipment rinsing water containing boscalid (point-source pollution). The results showed that the removal in both systems ranged from 49 to 100%. Mean removal rates were 76.3% and 72.4% in units. Results indicated thet HSF CWs are efficient systems in treating boscalid-polluted water.Chromium: This part included the investigation of chromium removal with the use of HSF-CWs (MG-C, MG-Z) and VF-CWs (W2, W3) and the chromium fate-distribution within a wetland environment. Apart from the continuous experiment (parallel operation and monitoring of pilot-scale CWs), batch experiments (kinetics and isotherm) were conducted in order to investigate the chromium adsorption capacity of the substrate material. According to the findings, HSF-CWs demonstrated higher removal capacities in comparison to VF-CWs, while in both types the planted units indicated better performance compared to the unplanted ones. The distribution of chromium in the various wetland compartments (substrate, plant, pore water) and annual mass balance calculation highlighted the exceptional contribution of substrate to chromium retention, while Cr accumulation in plant was not so high. Finally, experimental data fitted better to the pseudo-second-order and Langmuir models regarding kinetics and isotherm simulation.
Degree
thesis:*- Grantor dc:publisher
- Democritus University of Thrace (DUTH)
- Year dc:date
- 2017
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Papaevangelou, Vasiliki
- Παπαευαγγέλου, Βασιλική
Subjects
dc:subject × 37- Τεχνητοί υγροβιότοποι
- οριζόντιας υπόγειας ροής
- κατακόρυφης ροής
- κοινοί ρύποι
- Ενδοκρινικοί διαταρακτές
- boscalid
- Χρώμιο
- λειτουργικές και σχεδιαστικές παράμετροι
- Ισοζύγιο μάζας
- ισόθερμες προσρόφησης
- Κινητική προσρόφησης
- Constructed wetlands
- Horizontal subsurface flow
- Vertical flow
- university campus wastewater
- common pollutants
- Endocrine disrupting chemicals
- Chromium
- DESIGN AND OPERATION PARAMETERS
- Mass balance
- kinetic and isotherm experiments
- Περιβαλλοντική Μηχανική
- Επιστήμες Μηχανικού και Τεχνολογία
- Πράσινη και Αειφόρα επιστήμη και Τεχνολογία
- Διαχείριση και Διάθεση αποβλήτων
- Γεωεπιστήμες και Επιστήμες Περιβάλλοντος
- Φυσικές Επιστήμες
- Επιστήμες περιβάλλοντος
- Υδάτινοι πόροι
- Environmental Engineering
- Engineering and Technology
- Green and Sustainable Science and Technology
- Waste Management and Disposal
- Earth and Related Environmental Sciences
- Natural Sciences
- Environmental Sciences
- Water Resources
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/40537