University of Ioannina
Η επίδραση της θετικής τελο-εκπνευστικής πίεσης (ΡΕΕΡ) στη δομή και λειτουργία της δεξιάς και της αριστερής κοιλίας
Abstract
dc:descriptionIntroduction: Positive end-expiratory pressure (PEEP) improves oxygenation in patients with respiratory distress, but it can also adversely affect cardiac function. The aim of this study was to determine how low and moderate levels of PEEP affect left and right ventricular structure and function.Method: The study involved 14 patients under mechanical ventilation (pressure controlled). To perform the study, we used transesophageal echocardiography (M-mode, two-dimensional, Doppler, tissue Doppler) and 16 parameters were recorded. Measurements were performed initially with PEEP 0 cm Η2Ο, then 10 minutes after applying PEEP 5 cm Η2Ο and 10 minutes after applying PEEP 10 cm Η2Ο.Results: After applying PEEP 5 cm H2O, there was no statistically significant change observed in any parameter. In contrast, after the application of PEEP 10 cm H2O, significant changes in most parameters were recorded: Tricuspid annular systolic velocity (St) changed from 10,86±3,8 cm/sec (mean±SD) at ΡΕΕΡ 0 cm H2O to 8,7±2,9 at PEEP 10 cm H2O, Tricuspid Annular Plane Systolic Excursion (TAPSE) changed from 2,876±0,643 cm to 2,385±0,556 cm, right ventricular myocardial acceleration during isovolumic contraction (IVA) from 2,2692±0,93m/sec2 to 2,8536±1,628 m/sec2, pulmonary artery ejection time (ΕΤ) from 259,27±17,47 msec to 229,34±31,22 msec, right ventricular end-diastolic area (EDA) from 21,372±5,01 cm2 to 18,87±4,15 cm2, left ventricular eccentricity index at end-diastole from 0,9±0,07 to 0,99±0,08, left ventricular Stroke Volume (SV) from 85,574±29,34 ml to 74,131±31,9 ml, left ventricular Ejection Fraction (EF) from 51,41510,67% to 58,043±9,3%, early ventricular filling velocity (E wave) from 0,7337±0,15 m/sec to 0,6177±0,104 m/sec and E/A ratio of transmitral flow from 1,023±0,378 to 0,8786±0,23. After applying PEEP 10 cm H2O, a trend towards an increase in MPI index of right ventricle and a decline in end systolic area (ESA) of the right ventricle were recorded. With respect to other parameters (Right ventricular Fractional Area Change – FAC, left ventricular eccentricity index at end-systole, A wave and E/E΄ ratio of transmitral flow) no statistically significant differences were recorded.Conclusion: From above, it appears that applying PEEP 5 cm H2O has no effect in the structure and the function of the heart. In contrast, applying PEEP 10 cm H2O effects the structure and the function of the right ventricle; this is mainly attributed to reduced filling of the heart (reduced preload) and to a lesser extent to increased pulmonary vascular resistance (increased afterload). The left ventricle is not adversely affected, instead there is an increase in contractility recorded. Applying PEEP 10 cm H2O results in reduction of cardiac output .
Degree
thesis:*- Grantor dc:publisher
- University of Ioannina
- Year dc:date
- 2014
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Margaritis, Athanasios
- Μαργαρίτης, Αθανάσιος
Subjects
dc:subject × 20- Θετική τελο-εκπνευστική πίεση
- Μηχανικός αερισμός
- Προφορτίο
- Μεταφορτίο
- Διοισοφάγειος υπερηχοκαρδιογραφία
- Ιστικό doppler
- Κλάσμα εξώθησης
- Καρδιακή παροχή
- Positive end-expiratory pressure (PEEP)
- Mechanical ventilation
- Preload
- Afterload
- Trans-esophageal echo
- Tissue doppler
- Ejection fraction
- Cardiac output
- Ιατρική και Επιστήμες Υγείας
- Κλινική Ιατρική
- Medical and Health Sciences
- Clinical Medicine
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/40622