National and Kapodistrian University of Athens
Δοσιμετρία και βελτιστοποίηση των σύγχρονων μορφών ακτινοθεραπείας
Abstract
dc:descriptionIntroduction: Advanced Radiation therapy techniques such IMRT (Intensity Modulated Radiation Therapy) and VMAT (Volumetric Modulated Arc Therapy), offer great advantages over previously used techniques (2D, 3D CRT), both by reducing side effects and by more effectively controlling the disease by increasing the dose delivered to the tumor. The VMAT technique has the additional advantage, of the optimal tumor irradiation and simultaneous dose sparing of healthy tissues faster than IMRT.Purpose: The purpose of the study was to investigate whether it is possible to create the ITV using a reduced set of 4DCT phases in patient plans with moving targets and to investigate the dosimetric differences derived by different calculation algorithms in IMRT and VMAT patient plans.Methods: Ten lung cancer patients who had received 4DCT imaging as part of their treatment simulation, and who had a noticeable tumor motion were recruited as patients with moving targets. For each patient, a GTV, based on the original physician-drawn ITV was drawn on the exhale phase, (following the common clinical practice according to which the physician directly draws the ITV using the 4DCT images). This GTV was then propagated to the other phases of the 4DCT using a commercial image registration package (MIMVista, Cleveland OH). Different ITVs were created using N phases closest to exhale (N=1-10). For each ITV contour, a Rapid Arc (Varian Medical Systems, Inc. Palo Alto, CA) plan was created on the exhale phase CT, normalized so that the 95% isodose line covered at least 95% of the ITV. Each plan was applied to each CT phase (1-10), and the doses deformably mapped to the exhale phase. The effect of the motion was quantified in terms of the dose to the 95% of the target on the exhale phase (D95). The change in these parameters as N was reduced from 10 was calculated. Additionally, the difference in the 3D calculations of the original plans and the 4D calculations was noted as a function of N.Moreover, the accuracy of the Pencil Beam (PB) and the Monte Carlo (MC) calculation algorithms commonly used to determine the dose distribution in Intensity Modulated Radiation Therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) techniques. For this purpose, IMRT and VMAT plans were created for nine prostate patients using a commercially available treatment planning system (Monaco, Elekta Instrument AB Stockholm). All plans were optimized to be clinically acceptable and the final dose calculation was performed using a) the PB and b) the MC calculation algorithm. The plans were evaluated in the central coronal plane using the I'mRT Matrixx (IBA Dosimetry GmbH Schwarzenbruck) 2D-array placed in a solid water phantom a) by setting all control points to zero gantry degree and b) by leaving the beam orientation as planned. Evaluation was performed with OmniPro-I'mRT (IBA Dosimetry GmbH Schwarzenbruck) software using the gamma index method with acceptance criteria of 3% dose difference and 3 mm distance to agreement taking into account all points with dose values greater than the 10% of the normalized dose.Results: Regarding patients with moving targets differences in 3D and 4D dose calculations varied from 3% to 14% with an average of 7% for ITV_10/10. For 9 out 10 of ten patients we observe less than 5% reduction in the D95 by using ITV_8/10. For 3 out of ten patients we can have less than 5% reduction in the D95 by using ITV_7/10 and for 1 out of 10 patients we can patients we can have less than 5% reduction in the D95 by using ITV_6/10. Regarding dose calculation algorithms, results show that PB calculation algorithm can accurately determine the dose distribution applied to the I'mRT Matrixx 2D array when all control points were set to zero gantry degree for both IMRT and VMAT plans (average passing rates of 96.6 and 94.7% of the points passed the 3%/3 mm acceptance criteria, for IMRT and VMAT, were observed, respectively). On the other hand, considerable differences between the different calculation algorithms were observed when the actual (i.e. the planned) beam orientation was used for the plan verification. In this case, the PB algorithm was found adequate for dose determination only for the IMRT plan verification (an average passing rate of 91% was observed).Conclusions: There is no rule for reducing ITV in patients with the examined moving targets that works for all patients. Some reduction (8/10 phases) is possible for most of the patients but not all and also the volume reduction is small. Therefore what we are currently doing is reasonable. 4D dose calculations give different DVHs to 3D also shown by other groups. Reduction in ITV volume is possible for some patients (e.g. patient 2 17% reduction), but 4D dose calculation is necessary. For the VMAT plans, MC calculation algorithm was found significant superior compared to the PB dose calculation algorithm (average passing rates of 73.5 and 93% for the PB and the MC algorithms, were observed, respectively).
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2017
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Giakoumakis, Nikolaos
- Γιακουμάκης, Νικόλαος
Subjects
dc:subject × 6Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/40851