University of Patras

Μελέτη ειδικών χαρακτηριστικών φωτοβολταϊκών μονάδων και κυψελών καυσίμου σε αυτόνομο ηλεκτρικό σύστημα με συμβατικές και ανανεώσιμες πηγές ενέργειας

Abstract

dc:description

Standalone power systems that include renewable energy sources represent a powerful alternative option for isolated power generation at remote locations. The optimal sizing problem resulting from them is a challenging combinatorial optimization problem, and its solution may prove a very time-consuming process. Chapter B of this Thesis investigates the performance of a standalone power system by proposing many alternative hybrid systems that were modeled, optimized and simulated using Hybrid Optimization Model for Electric Renewable (HOMER) considering the problem from an economic point of view. The method has been successfully applied to a typical representative case of a power system in a village in Cyprus that is named Choulou. The design variables were combinations of wind generators, photovoltaic modules, Diesel generator, batteries and converter. The performance of the optimization methodology is studied for many alternative scenarios via sensitivity analysis, and the optimal combination was the hybrid system Wind Generator - Photovoltaic modules - Batteries in terms of quality and convergence, compared to the solutions provided by the Preinstalled system as well as the rest of the systems that were also analyzed. The simulation results are mainly based on the lowest total net present cost (NPC) while the objective function was the minimization of systems cost of energy (€/kWh). The exponential growth of photovoltaic systems raises serious questions regarding their operational security, especially, under difficult weather conditions, such as a lightning strike event. The issues related to the protection of electrical installations that incorporate photovoltaic modules are also one of the research objectives of this thesis. Therefore, in chapter C of this Thesis a simplified model for the ground system of a photovoltaic park, which is located on Cyprus island and is consisted of a typical arrangement of solar-modules, was investigated. Simulations were carried out in ATP - EMTP program, taking into account the phenomenon of the ionization of the ground, in order to approximate the behavior of grounding systems in transient phenomena Such as lightning induced overvoltages in the system. Models, with no constrained parameters (pi equivalent circuit, with lumped R-L-C elements) were used for the ground grid as a circuit approach. In chapter D of this Thesis the electrical characteristics of photovoltaic (PV) modules after being subjected to high impulse voltages, which are usually generated by lightning or switching surges, were examined. Tests were conducted at the High Voltage Laboratory of the University of Patras in Greece on PV modules of 5 and 195 Wp derived from different manufacturers, by performing various stress scenarios. The I-V and P-V characteristic curves of the examined modules, before and after the impulse voltage stress tests (using typical impulse voltage waveform, 1.2/50 μs), are compared with each other considering the modules' ability to maintain their nominal electrical characteristics. Attention was systematically given to the quality of the measured results due to the potential inherent uncertainty of the equipment and the measuring configuration. After certain periods of time, the electrical performances of the stressed modules are examined again in order to ensure whether they regain some or all of their properties in case of prior differentiation. The experimental results are compared with theoretical estimations, so as to confirm the rightness of the presented procedure.Taking into account the results of our previous study on the impact of the impulse voltage on the photovoltaic modules properties and so as to have a more comprehensive examination of the issue, the experiment was repeated in Chapter E of this Thesis by utilizing even more recent photovoltaic modules and by introducing new data and parameters for processing. The new objective was to determine the boundary conditions of possible total collapse of the module's insulation where the potential of serious damage on the modules properties (degradation or even end of operation) will be significantly increase. Tests were carried out in accordance with IEC 61730-2: 2009 and its revision (IEC 61730-2: 2016) on a 200 Wp single crystalline silicon/sc-Si photovoltaic module, while one of the main claims of the present work refers to extreme tests with voltage levels far beyond those proposed by the above Standards. The performance was evaluated by means of I-V and P-V characteristic curve recording for the module under test, followed by a detailed comparison with the corresponding curves of a reference module. The data are reduced to Standard Tests Conditions according to IEC 60891:2009. Special attention was paid on the consideration of possible sources of inherent measuring errors, for reliable comparison between the reference and the stressed module. The results suggest that, neither power nor mechanical degradation is induced on the photovoltaic module for voltages up to the limits imposed by the IEC 61730-2: 2016 (i.e. 12 kV peak). Interestingly, the module withstands voltages up to 35 kV peak, as far as the rest procedure of the Standards is strictly followed. Finally, tests in ‘‘rod-to-module” gap were performed (by utilizing a (sc-Si) 195 Wp module) to simulate direct lightning strikes on the module, which were concluded that a peak voltage as high as 144 kV was needed for destructing the module, both electrically, thermally, and mechanically.The aim of Chapter F of this Thesis is the evaluation of the performance of a low pressure Proton Exchange Membrane FC (PEMFC) stack in step load changes, which are characteristic in applications of standalone FC systems. Firstly, the electrical behavior of a PEMFC was investigated via its Voltage - Current (V-I) characteristic curve. The latter was derived from the changes in the FC voltage and current outputs which arise from step load changes. In principle, step load changes influence the electrochemical process resulting in the variation of the values of significant parameters such as temperature, pressure, purge status etc. The above values were registered and evaluated. Secondly, a model of the system was simulated using Matlab/Simulink, while PCUs (power conditioning units) were added in order to control power flow for enhanced performance. Finally, both operational and simulation results were compared to each other pointing out that back up PCUs are essential for the smooth operation of the system and for optimum system performance. The analysis of the experiment is based on a low pressure 1.2 kW PEMFC stack (NEXAS power module).The objective of Chapter G of this Thesis is to study the way by which the requirements of a load can be covered through a Proton Exchange Membrane Fuel Cell (PEMFC) that is fed with hydrogen located on metal hydride canisters (MHCs), for as long as possible. The heat transfer rate determines the way by which hydrogen can be extracted from a canister and thus the control of this parameter is important for optimizing the design of metal hydride hydrogen storage applications. A PEMFC-MHCs system was examined through monitoring the changes in the values of temperatures, pressures and fuel consumption in time for various examined loads. After the incorporation of a Heat Exchanger (HExch) on the MHCs’ operation, the temporal distributions of temperatures, pressures and fuel consumption were plotted again and were compared with the prior measurements targeting on the enhancement of the system’s performance. The results showed a significant increase in the capacity of the MHCs to provide the necessary amount of hydrogen for covering the load demands so that the system can operate for longer time than in the case without the HExch. Primary motivation of this study is to examine potential future partially replacement of the commonly used batteries (e.g. in a photovoltaic system) with FC-MHCs systems as an alternative auxiliary power source due to the comparative advantages that these systems indicate in relation to batteries.Finally, in Chapter H of this Thesis the most recent developments in anti-islanding techniques for distributed resources like photovoltaic systems are reviewed. The techniques may be classified as remote or local. Remote techniques are associated with island detection on the utility side while local techniques are associated with island detection on the distributed power generation side. Local techniques may further he classified as passive and active. This part of the work also provides a detailed description of the Reactive Power Variation/RPV islanding detection method by applying a variant of the method to the EMTP simulation program (Based on a recent publication in the international literature). The peculiarity of the applied method in relation to the most conventional method of intermittent bilateral reactive power variation (IB-RPV) is that the reactive power produced in each period is either positive or negative and not in both directions.

Degree

thesis:*
Grantor dc:publisher
University of Patras
Year dc:date
2017

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Naxakis, Ioannis
  • Ναξάκης, Ιωάννης

Subjects

dc:subject × 6

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/41184

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Naxakis, Ioannis; Ναξάκης, Ιωάννης. Μελέτη ειδικών χαρακτηριστικών φωτοβολταϊκών μονάδων και κυψελών καυσίμου σε αυτόνομο ηλεκτρικό σύστημα με συμβατικές και ανανεώσιμες πηγές ενέργειας. University of Patras, 2017. http://hdl.handle.net/10442/hedi/41184