Σύγκριση αιμοδυναμικών παραμέτρων μεταξύ της βηματοδότησης ταυτόχρονα δύο θέσεων της δεξιάς κοιλίας και της αμφικοιλιακής βηματοδότησης σε ασθενείς με συστολική δυσλειτουργία της αριστεράς κοιλίας

Abstract

dc:description

BACKGROUND AND OBJECTIVES: Cardiac resynchronization therapyconfers symptomatic and prognostic benefits to selected patients with congestive heartfailure. However, left ventricular lead implantation is technically unsuccessful in up to13% of cases.The primary aim of this study was to evaluate bifocal right ventricular pacingas a modality of cardiac resynchronization therapy in patients with severe congestiveheart failure and significant intraventricular conduction delay and to compare itsbenefits with biventricular pacing.We also compared the acute hemodynamic changes associated with pacing theright ventricular apex or outflow tract alone, the left ventricle alone, or biventricularpacing of the RVA and LV together.The optimal RV pacing site for cardiac resynchronization remains unclear.The present study compared the acute hemodynamic response to biventricular pacing,at two different right ventricular stimulation sites: right ventricular apex and outflowtract.METHODS AND RESULTS: Acute hemodynamic findings were measuredin 15 patients with severe heart failure and intraventricular conduction defect.Steerable pacing catheters were placed in the high right atrium, right ventricular apex,right ventricular outflow tract and the lateral wall of the left ventricle. Using apulmonary artery flotation catheter (Opti-Q) diastolic pulmonary artery pressure(DPPA) and cardiac index (CI) were measured in different pacing configurations: Comparison between Baseline and left ventricle-based pacingPacing of either the left ventricle alone or in combination with rightventricular pacing resulted in a significant improvement in a number of hemodynamicvariables compared with those observed under basal conditions. Both biventricularpacing modes induced a significant increase in cardiac index (AAI: 2.79±0.46,Apex+LV: 3.08±0.53, Out+LV: 3.02±0.57, p<0.01) and a significant decrease in QRSduration (AAI: 152±16, Apex+LV: 131±21, Out+LV: 133±18, p<0.01). There was nosignificant difference in mean arterial blood pressure between these two pacingprotocols. DPAP decreased significantly during Apex+LV pacing compared withAAI while Out+LV pacing resulted in a nonsignificant decrease in DPAP (AAI:23.45±5,61, Apex+LV: 20,45±7,12, p<0.01 Out+LV: 21.09±6,36, NS).The mean CI increased during pacing of the left ventricle alone compared withthe index obtained during AAI pacing, however, the difference trended towardsignificance (p value 0.06). Compared with AAI pacing, LV pacing was associatedwith a decrease in DPAP (23,45±5,61 vs 19,91±7,88, p<0.01). QRS duration, andmean arterial pressure were not significantly modified between these two pacing sites.Comparison between baseline and right ventricle-based pacingWhen mean CI values under baseline conditions and after right ventricle-basedpacing were compared, there were no significant differences, however, with bifocalpacing (Out+Apex) there was a non significant increase in CI while pacing from theapex resulted in a non significant decrease in CI. The lowest value of QRS width wasfound during Out+Apex pacing (NS) and the highest value during Apex pacing thatwas even higher than that during Out pacing (AAI: 152±16, Apex: 179±16, Out:176±19, p<0.01. The pacing site associated with the highest mean arterial pressurewas the Apex (p<0.05). Although Out pacing increased mean arterial pressurecompared with AAI pacing the difference was not significant. Bifocal pacing left thisparameter unchanged (NS). No significant differences in diastolic pulmonary arterypressure were observed between AAI and right ventricle-based pacing.Comparison between Apex+LV and Out+LV pacing.Acute hemodynamic results comparing Apex+LV with Out+LV pacing weresimilar.Comparison between biventricular and LV pacing.No significant differences in hemodynamic parameters and QRS duration werefound.Comparison between bifocal and LV based pacing. Although LV-based pacing provided better hemodynamics than did bifocalpacing the differences in the measured parameters did not reach statisticalsignificance.Comparison between bifocal and single site right ventricular pacing.Out + Apex pacing was associated with higher CI (p=0.06), narrower QRS (p=0.01)and lower pulmonary diastolic pressure (p=0.09) compared with either Apex or Outpacing.CONCLUSIONS: This acute hemodynamic study in patients with heart failure andintraventricular conduction defects, demonstrated that although bifocal rightventricular pacing should not be chosen as an initial treatment method, it may be anacceptable alternative in patients with LV implantation failure who refuse surgical LVlead placement or in whom such a procedure appears to be too risky.Left ventricular pacing and biventricular pacing provide similar hemodynamicresults.Bifocal pacing seems to be hemodynamically efficient or at least less harmfulthan right ventricular apical or right ventricular outflow tract pacing.The right ventricular stimulation site (Apex or Outflow tract) duringbiventricular pacing is of no importance.atrial pacing (AAI) mode, used as reference, bifocal right ventricular DOO pacing(Out+Apex) (pacing at right ventricular apex and outflow tract simultaneously),biventricular DOO pacing with the right ventricular lead placed either at the apex(Apex+LV) or at the outflow tract (Out+LV), DOO pacing in the right ventricularapex (Apex), DOO pacing in the right ventricular outflow tract (Out), and single-siteleft ventricular DOO pacing (LV). During each pacing mode the QRS width andarterial pressure were also measured. Statistical analysis was performed withcommercial software using repeated-measures ANOVA with posthypothesis testing ofpacing site differences by Tukey’s test.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2013

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Manolatos, Dimitrios
  • Μανωλάτος, Δημήτριος

Subjects

dc:subject × 10

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/41281

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Manolatos, Dimitrios; Μανωλάτος, Δημήτριος. Σύγκριση αιμοδυναμικών παραμέτρων μεταξύ της βηματοδότησης ταυτόχρονα δύο θέσεων της δεξιάς κοιλίας και της αμφικοιλιακής βηματοδότησης σε ασθενείς με συστολική δυσλειτουργία της αριστεράς κοιλίας. National and Kapodistrian University of Athens, 2013. http://hdl.handle.net/10442/hedi/41281