Αξιολόγηση της αξιοπιστίας της μέτρησης της αρτηριακής πίεσης με ταλαντωσιμετρική τεχνική σε ασθενείς με κολπική μαρμαρυγή: 24ωρή διακύμανση της αρτηριακής πίεσης, μεταβλητότητα και συσχέτιση με υπερηχοκαρδιογραφικούς δείκτες

Abstract

dc:description

INTRODUCTION: Arterial hypertension is the most prevalent modifiable cardiovascular risk factor affecting 20-40% of the adult population in developed countries, while atrial fibrillation is the most common arrhythmia affecting 1-2% of the general population and especially the elderly. To date the absence of arrhythmia has been an exclusion criterion in all validation studies of automated devices for blood pressure (BP) measurement. Thus, very few validation studies of automated BP monitors have been performed in patients in atrial fibrillation. Furthermore, several studies demonstrated an association of BP variability with target organ damage independently of the average blood pressure levels. This study aimed to investigate: a) the BP measurement accuracy of an automated device for BP measurement in patients with atrial fibrillation and b) the assessment of BP variability in atrial fibrillation and its association with echocardiographic indexes.ΜETHODS: A validation study of an automated oscillometric BP monitor was performed according to the European ESH-IP 2010 protocol in patients with permanent atrial fibrillation, untreated or treated for hypertension with stable treatment for 4 weeks. In the second part of the study patients in atrial fibrillation were assessed with BP measurements in office and out of office (24-hour ambulatory or home BP monitoring). The diagnosis of atrial fibrillation was confirmed with 12-lead electrocardiogram. Echocardiography was performed to evaluate left ventricular mass and left atrial diameter. Finally the BP variability was evaluated in patients in atrial fibrillation by using the indexes: (1) standard deviation [SD], (2) coefficient of variation [CV] and (3) time rate index [TRI]) and their association with echocardiographic indexes was assessed.RESULTS: For the validation study 53 patients were evaluated (mean age 72.7±8 years, 24 women). The inter-observer variability was 0.1±3.9 / 0.1±4.3 mmHg (for systolic/diastolic BP) (SBP/DBP) and the intra-observer variability was 1.6±6.2 / 0.1±3.9 mmHg. The mean SBP difference between oscillometric device and mercury sphygmomanometer was 2.3±7.7 mmHg and DBP 6±6.2 mmHg. The absolute differences of SBP among the two methods were 55% within 5 mmHg, 79% within 10 mmHg and 96% within 15 mmHg, whereas for DBP they were 52%, 77% and 86% respectively (pass criteria of ΕSH-IP validation protocol: ≤65%, ≤81% and ≤93% for differences within 5, 10 and 15 mmHg). Evaluation of the algorithm detection of atrial fibrillation showed that 90,2% of the detections were true positive, 7,1% false negative and detection failure occurred in 2,7% of the measurements. In the second part of the study 34 patients in atrial fibrillation were evaluated (72,5±6,7 years, 35,3% women). The left ventricular mass index (LVMI) (mean 110 ± 26,1 g/m²) was positively correlated with left atrial diameter (LAD) (mean 49,5 ± 5,5 mm) (r=0,57, p<0,01) and the automated office pulse pressure (51,2 ± 14,9 mmHg) (r=0,36, p<0,05). Moreover, left atrial diameter was positively correlated with 24-hour SBP (120,3 ± 15,6 mmHg) (r=0,4, p<0,05), home SBP (SHBP) (131 ± 13,3 mmHg) (r=0,6, p<0,05), 24-hour pulse pressure (45,5 ± 7,7 mmHg) (r=0,64, p<0,01), and with automated office pulse pressure (51,2 ± 14,9 mmHg) (r=0,38, p<0,05). In multiple regression analysis only 24-hour systolic BP was indepedently correlated with left ventricular mass index (Β= 1,15, ρ<0,05) and respectively 24-hour pulse pressure was associated with left atrial diameter in patients in atrial fibrillation (Β=0,44, ρ<0,05). In the third part of the study 84 patients with 24-hour BP measurement were assessed (mean age 72.8±6.2 years; 50 men; 42 in atrial fibrillation; MicrolifeWatchBP O3 n=42; Spacelabs 90207 n=42). The mean of accurate measurements was slightly higher in patients in sinus rhythm comparable with those in AF (n=59.7±9.1 vs. 53±10.8 respectively, p<0.05). Regarding SBP there was no difference in day/night BP (127.8±15 / 117.1±18.1 vs. 127.3±14.4 / 114.3±14.2 mmHg) and in standard deviation SD of day/night SBP (13.7±4.3 / 11.5±3.6 vs. 12.8±3 / 11.5±3.3 mmHg), CV (Coefficient Variation) (0.11±0.04 / 0.10±0.03 vs. 0.10±0.02 / 0.10±0.03) and TRI (Time Rate Index) (0.48±0.14 / 0.47±0.14 vs. 0.48±0.14 / 0.45±0.15 mmHg/min), (p=NS). Regarding DBP, higher values of BP day/night, (77.5±9.8 / 69±12.9 vs. 71.6±7.5/61.2±7.4 mmHg), higher SD (10.3±2.9 vs. 8.2±2.2 mmHg), higher day CV (0.13±0.04 vs. 0.11±0.03) and higher day/night TRI (0.37±0.09 / 0.36±0.10 vs. 0.32±0.09 / 0.28±0.08 mmHg/min) in patients in AF, taking into consideration the higher baseline DBP compared to pts in SR.In a substudy 25 patients with AF were evaluated (mean 72,7±6,6 years, 8 women) and the left ventricular mass index (113,9±23,1 g/m²) was positively correlated with the 24h day SBP SD (10,3± 2,5) (r=0,39, p<0,05) the 24-hour SBP (120±14,1 mmHg) (r=0,43, p=0,052) and the time rate index of 24-hour SBP (0,48±0,13) (r=0,44,p<0,05). Additionally left atrial diameter (mean 49,9±5,2 mm) was statistically significant positively correlated with SD of 24-hour SBP (10,3±2,5) (r=0,57, p<0,05), with day SD 24-hour SBP (14,6 ±4,8) (r=0,6, p<0,05), coefficient of variation of day 24h SBP (0,12 ± 0,04) (r=0,47, p<0,05), the TRI of 24-hour SBP (0,48 ± 0,10) (r=0,57, p<0,05) and with the TRI of day 24-hour SBP (0,48±0,13) (r=0,72, p<0,05). Additionally only TRI of day 24-hour SBP correlated, independently of age and 24-hour r BP assessment, with left ventricular mass index (Β=0,437, ρ<0,05). The same index (Β=0,618, ρ<0,001) and age (Β=0,402, ρ<0,05) were positively correlated with left atrial diameter. CONCLUSIONS: The main findings of the current thesis are that: a) In elderly subjects with atrial fibrillation a validated automated oscillometric device for BP measurement appears to be reliable in measurement SBP but not so DBP, b) The algorithm of the device for detecting atrial fibrillation appears to be reliable. c) In atrial fibrillation left ventricular mass and left atrial diameter are correlated with office and 24-hour SBP, automated office and 24-hour pulse pressure, yet no correlation of DBP was found with these echocardiographic indexes. Therefore, in atrial fibrillation automated measurements of SBP can predict the subclinical organ damage. d) Patients in atrial fibrillation compared to patients in sinus rhythm have no difference in SBP variability assessed by 24-hour monitoring, and regarding the different baseline DBP values significant DBP variability difference. e) We finally found a weak correlation, more studies needed to be confirmed, of subclinical target organ damage, such as left ventricular hypertrophy and diastolic dysfunction and left atrial enlargement, with SBP variability assessed with automated 24-hour BP monitors in elderly subjects in atrial fibrillation.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2017

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Destounis, Antonios
  • Δεστούνης, Αντώνιος

Subjects

dc:subject × 13

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/41350

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Destounis, Antonios; Δεστούνης, Αντώνιος. Αξιολόγηση της αξιοπιστίας της μέτρησης της αρτηριακής πίεσης με ταλαντωσιμετρική τεχνική σε ασθενείς με κολπική μαρμαρυγή: 24ωρή διακύμανση της αρτηριακής πίεσης, μεταβλητότητα και συσχέτιση με υπερηχοκαρδιογραφικούς δείκτες. National and Kapodistrian University of Athens, 2017. http://hdl.handle.net/10442/hedi/41350