National and Kapodistrian University of Athens
Η συμβολή της συνδυασμένης χρήσης των υπερήχων power doppler, 3-D και 3-D power doppler στην διάγνωση της παθολογίας του σώματος της μήτρας
Abstract
dc:descriptionObjective: To determine the role of 3-Dimensional Ultrasound(3-D) and Power Doppler (3-DPD) in the diagnosis of the uterusmalignancy and to examine the diagnostic accuracy of this newultrasonographic technique in the detection of uterine cancer.Methods: A preoperative analysis by 3-D and 3-DPD wasperformed between November 2003 and November 2012 of 636 womenreferred uterine bleeding within the first Department of Obstetrics andGynecology, University of Athens, in Alexandra Hospital. The age ofthe women studied was 47,418,8 years with a range (18-72 years).Three dimensional ultrasonographic method is a new diagnostictechnique that provides precise and additional information of theregion of interest by the rotation of the mechanical transducerthrough 360ο. Multiple sections of uterine pathology, rotation in thethree axis (x, y, z), translation and reconstruction of (3-D) plasticimages allow more meticulous and detailed evaluation, especiallywhen modes used.Comprehensive (3-D) display allows interactive qualitative andquantitative analysis of the tumor microcirculation in threedimensions.In the present study, were analyzed 4 sonomorphologicalcriteria (endometrial thickness, endometrial volume, subendometrialhallo, intracavitary fluid) and 3 criteria by 3-DPD (vessel’sarchitecture, branching pattern and tumoral blood flow (R.I.)), basedon Kurjak’s scoring system. When it was necessary some patientswere evaluated more detailed with imaging techniques (CT scan,M.R.I.), tumor markers, and at last were noted the family andpersonal history and analyzed demographic considerations.All of the women were operated and comparison of theultrasound findings with the histopathological diagnosis wasconducted. The malignant of the uterus lesions were classified according to the International Federation of Gynecologists andObstetricians (F.I.G.O).Statistical analysis: The diagnostic accuracy of 3-D ultrasoundwas estimated by R.O.C. curve and for statistical analysis of the data,was used the x²-test.Results: In the present study was included the largest numberof patients (636 women) according to international literature. Thewomen that were in reproductive age were examined independently ofthe phase of their menstrual cycle (proliferative or secretory) thusproviding a more objective result.The histopathological diagnoses were 450 benign tumors of theuterus and 186 malignant. The combined use of 3-D and 3-DPD wasshowed 430 benign and 206 malignant tumors of the uterus. A cut offvalue of 6 was used for the discrimination of benign and malignanttumors based on a specific scoring system concerning 3-Dultrasonographic criteria.Three dimensional methods diagnosed 12 malignant tumors asbenign (false negative) and 32 benign tumors of the uterus asmalignant (false positive). The combined morphologic and threedimensional Power Doppler examination of the uterus lesions reachedsensitivity and specificity 93,5% and 92,9% respectively while P.P.V.was 84,5% and N.P.V. was 97,2%.The 3-D ultrasound analysis with high score (>6) was associatedwith malignant histopathological types, with older women (54,7±10,5years) with low social economical level (p=0,0034), with family history(p=0,999), with more than two coffees per day, with a history of breastcancer (p=0,010) and with hypertension (p=0,017). It has also to bereported that was a statistical significance between clinical symptomsand the high score of 3-D ultrasonographic criteria (p<0,001).C.T. was also statistically correlated with uterine malignancy(p<0,001). Serum cancer markers such as Ca125, CEA, Ca15-3 werestatistically correlated with high score (>6), indicative of the uterusmalignancy (p<0,001). In the present study was also proved a statistically significancebetween high score and the stage of the uterus cancer (p>0,027), theprobability of metastatic disease and the grade (borderline correlation:p=0,078).Conclusions: Even if color transvaginal ultrasonographicmethod has been established as a worthy and effective technique inthe estimation of uterine neoplasms has the disadvantage not to viewthe uterus lesion entirely. On the contrary, 3-D sonographic analysishas the advantage of precise location, and measurement the uterinetumor and allows multiplanar presentation of the capsule infiltrationfor the meticulous estimation of the uterus lesion and at last, 3-Dimaging shows abnormalities of neovascularization vessels with smalldiameter (<1mm) for the study of uterus tumor microcirculation.The advantages, of the combined use of 3-D and 3-DPD are:1. Objective diagnosis of the uterine neoplasms and discriminationof them in benign-malignant in order to reduce false negativeand false positive results.2. The contribution of this ultrasonographic method in thediagnosis of early stage I uterine cancer.3. The reduction of examination’s time and patient’s discomfort.Three dimensional ultrasound is a new emerging technologywith a high level of diagnostic accuracy and main purpose thesignificant reduction of morbidity and mortality of the uterus cancer.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2013
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Skartados, Nikolaos
- Σκαρτάδος, Νικόλαος
Subjects
dc:subject × 12Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/41407