Λοξή διαφυσιακή οστεοτομία 1ου μεταταρσίου (Ludloff) για την διόρθωση βλαισού μεγάλου δακτύλου: συγκριτική εμβιομηχανική μελέτη δύο τύπων

Abstract

dc:description

The term Hallux Valgus was first mentioned by Carl Hueter in 1870. The hallux valgus complex is characterized as a combined deformity with a malposition in the first metatarsophalangeal (MTP) joint with lateral deviation of the great toe and medial deviation of the first metatarsal bone. It is the most common pathology of the big toe. In weight bearing AP radiographs, specific angles have been defined to quantify the deformity. The hallux valgus angle (HVA) is defined as the angle between the shaft axis of the first metatarsal and the proximal phalanx of the hallux. Angles greater than 15ο are pathological. The intermetatarsal angle (IMA) is the angle between the shaft axis of the first and second metatarsal. Values more than 9ο are consider as pathological. It is generally accepted that hallux valgus occurs in steps, frequently on a background of several predisposing factors; a) Extrinsic : High-heeled narrow shoes, Excessive weight-bearing. b) Intrinsic : Genetics, Ligamentous laxity, Metatarsus primus varus, Pes planus, Functional hallux limitus, Sexual dimorphism, Age, Metatarsal morphology, First-ray hypermobility and Tight Achilles tendon. Evaluation of the hallux valgus due to the best treatment choice, starts with careful history-taking considering possible contraindications for surgical treatment. Basic criteria for surgical treatment are pain and functional annoyances rather than the aesthetic problem. Non-surgical care should especially be considered in patients with general hypermobility, ligamentous laxity or neuromuscular disorders, and of course in the presence of absolute contraindications to surgical correction like a relevant peripheral arterial vessel disease, or relative contraindications like diabetes or smoking. Non-operative treatment includes footwear modification, night splints, physiotherapy or insoles. Non-operative treatment will not correct the deformity, but can relieve its symptoms. More than 100 different procedures have been proposed for the correction of hallux valgus deformity. In cases involving HVA and IMA greater than 35ο and 15ο, respectively, proximal or shaft metatarsal osteotomies with a concomitant distal soft tissue procedure have proved to be effective in obtaining adequate correction. The Ludloff osteotomy is considered as an effective procedure for these deformities. It is an oblique osteotomy of the first metatarsal bone and as originally described in 1918, the osteotomy was performed without any fixation. In the mid-1900s, Myerson et al. re-introduced the procedure, using two interfragmental compression screws for fixation. Problematic issues associated with use of the Ludloff osteotomy, similar to other proximal and shaft osteotomies, include inherent instability, delayed union, dorsal malunion, and fixation failure with loss of correction. Several of our patients showed up with loss of correction or periosteal bone formation which suggests motion at the osteotomy site. We suggest the use of a medial mini locking plate as a supplementary fixation. Our clinical outcomes were quite satisfactorily. There was no loss of correction or periosteal bone formation. To test the hypothesis that supplementary use of the medial mini locking plate would improve the stability associated with the Ludloff osteotomy compared with standard fixation using 2 interfragmental compression screws, we undertook the bone model investigation using 20 identical Sawbone (Pacific Research Laboratories, Vashon, WA) models. To meet the demanding needs of the in vitro experiments, to more closely simulate natural cortical bone, and to account for the variable bone quality arising from the used of cadaver foot specimens, we used fourth-generation composite cortical bone models. This ensured the enhancement of properties such as fracture toughness, fatigue life, tensile strength and modulus, and thermal stability. The first 10 specimens (group A). A Ludloff oblique osteotomy was performed and each specimen underwent the same amount of correction and fixation with 2 interfragmental screws. The next 10 specimens were designated as (group B). After completion and fixation of the osteotomy just in group A, a 4-hole, 2.4-mm titanium mini locking plate was applied on the medial surface, with the most proximal and distal screws inserted in the plantar and dorsal fragments, respectively. All specimens were then prepared for mechanical testing. Two holes were drilled on the medial aspect of the proximal and distal fragments, and a 50-mm gauge length extensometer (Instron G51-14-M-A, Instron, High Wycombe, Bucks, UK) was then placed into the drilled holes to provide accurate measurements of the fracture gap (deflection) across the osteotomy during loading. The base of each specimen was then clamped (EARTH CHAIN model EY-4, Indianapolis, IN) with the metatarsal inclined 15ο from the horizontal to simulate the anatomic standing position, with the plantar aspect of the metatarsal facing upward. The plantar aspect of the metatarsal head then loaded using a loading ram in a cantilever-bending mode with o moment arm averaging 55.5mm using a servohydraulic MTS Mini Bionix 858 test frame (MTS Systems, Eden Prairie, MN).The loading rate was set equal to 1mm/min to simulate quasistatic conditions during the tests. The load was applied continuously until failure of the fixed osteotomy occurred. Failure was defined as fracture and/or implant pull out, a 2-mm osteotomy displacement, or when the load decreased to 75% of the maximum load recorded, whichever came first. The load was measured as units of force in Newtons (MTS661.11 Force Transducers, 500-N capacity, Eden Prairie, MN), and the data were recorded at a rate of 1Hz. The measured forces were transformed in pressure units (Mpa) considering as loading surface the metatarsal head (2.5cm2). Data collection was performed using Multipurpose Testware (MTS Systems, Eden Prairie, MN) and statistical analysis and plotting of the results were performed using Microsoft Excel (Microsoft, Bellevue, WA.) and OriginPro (Origin Lab, Northampton, MA) software. The following parameters were studied: 1. Load to failure. 2. Stiffness. 3. Absorbed energy. Load versus loading ram displacement curves were obtained for each specimen, and the stiffness of the fixation was calculated as the slop at the initial linear part of the curves at 0 to 100N of force. The energy absorbed until failure for each specimen was determine by calculating the area under the load versus loading ram displacement curve until failure point. The mean average values of load to failure, stiffness and absorbed energy between the 2 groups were analyzed using unpaired Student’s paired ξ tests, and statistical significance was defined at the 5% level (p≤0.05). No statistically significant difference in stiffness was found between the specimens of the 2 groups (p=0.21). The difference between the 2 groups for the mean average load to failure was statistically significant (p=0.025). The difference between the 2 groups for the mean average energy absorbed before failure was also statistically significant (p=0.05). The results observed in our investigation showed that the mini locking plate combined with interfragmental compression screws did not demonstrate statistically significant difference in stiffness compared with the sole screw construct. Our results did demonstrate, however, that supplementary fixation of the Ludloff osteotomy with a mini locking plate created a stronger (greater load and energy absorbed before failure) construct than the sole screw technique, when identical fourth generation composite Sawbone models were used to eliminate any differences in model bone quality and anatomy, paramount for demonstrating the relative differences between different types of internal fixation. With the supplementary fixation we believe that the strength of the fixation construct gained.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2017

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Tsilikas, Stavros
  • Τσίλικας, Σταύρος

Subjects

dc:subject × 10

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/41423

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Tsilikas, Stavros; Τσίλικας, Σταύρος. Λοξή διαφυσιακή οστεοτομία 1ου μεταταρσίου (Ludloff) για την διόρθωση βλαισού μεγάλου δακτύλου: συγκριτική εμβιομηχανική μελέτη δύο τύπων. National and Kapodistrian University of Athens, 2017. http://hdl.handle.net/10442/hedi/41423