University of Ioannina
Λοξή οστεοτομία κνήμης χωρίς την αφαίρεση οστικού τμήματος και οστεοτομία κνήμης με αφαίρεση οστικής σφήνας για διόρθωση του οστεοαρθριτικού γόνατος: συγκριτική μελέτη της σταθερότητας της οστεοσύνθεσης με γωνιώδη πλάκα
Abstract
dc:descriptionAim: This experimental study was performed in order to evaluate the biomechanical behavior of two different types of high tibial osteotomy (HTO). The first one is an HTO without bone removal (O-HTO), and the second one is a double-level retrotuberckle closed HTO (S-HTO). Even though their shape and geometry is different, they are stabilized with the same type of internal fixation; an angular blade plate. Therefore, the study focused on the influence of the geometry of the osteotomy in its stability.Material and methods: Fourteen (14) 3rd generation composite tibia models were used, with a pre-built 13° varus deformity of their proximal articular surface. Seven (7) of them were used for the O-HTO group and the rest (7) for the S-HTO group. Using special custom-made jigs the repeatability of each of the osteotomies was achieved. The load protocol consisted of cyclic sinusoidal axial load that was applied to each specimen. The load was applied from 100 to 500 N for 2.000 cycles at 1Hz.Results: No specimen or construct failure was observed during the tests. The tibias of the O-HTO group showed slightly better biomechanical performance compared with the tibias of the S-HTO group. The mean stiffness of the O-HTO group was 2,480.44 N/mm (±436.77) and of the S-HTO group was 2,059.47 N/mm (±421.65) (p<0.001). Respectively, the relative displacement of the load cell of the load machine during the cycles was smaller in the O-HTO group. The mean relative displacement of the load cell in the O-HTO group was 166.7 μm (±34.6) and of the S-HTO group was 202.7 μm (±44.8) (p<0.001). This displacement reflects the potential motion in between the osteotomy surfaces in each specimen. This value showed a consistent width during the cycles, with a negative linear regression inthe S-HTO group, which is indicating stability of the respective constructs.Conclusion: The analysis of the results revealed that both types of HTO showed a similar biomechanical behavior during the specific load conditions that were used in this experiment. The slight better performance of the O-HTO specimens could have been attributed to technical details during the preparation of the constructs. The O-HTO specimens were inevitably pre-loaded more compared with the S-HTO specimens during their fixation, which might have influenced their behavior. However, in both types of HTO the relative displacement of their osteotomy surfaces was considered to be in between the accepted range of 100 – 500 μm which is necessary for achievement of primary bone healing.For the specific load protocol that was used during the tests, one can assume that the behavior of the specimens was mainly driven by the presence of the angular blade plate that was used for their fixation and secondarily by the geometry of the osteotomy surfaces.
Degree
thesis:*- Grantor dc:publisher
- University of Ioannina
- Year dc:date
- 2015
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Stavlas, Panagiotis
- Σταυλάς, Παναγιώτης
Subjects
dc:subject × 16Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/41475