Back to search

Democritus University of Thrace (DUTH)

Διερεύνηση της δυναμικής απόκρισης ιστορικών μνημείων λικνιζόμενων υπό σεισμική διέγερση και της συνεισφοράς εφεδράνων τριβής πολλαπλής καμπυλότητας στη σεισμική τους θωράκιση

Abstract

dc:description

In the present thesis the seismic response of rigid rocking structural systems is investigated. Specifically the response of monumental structures is examined in this study. These structures such as free – standing columns colonnades and masonry arches consist representatives of rigid rocking SDOF oscillators.The original scientific contribution of the present thesis is categorized into three individual sections. In the first section a methodology that assesses the seismic vulnerability of the examined rocking systems based on the selection of the ground intensity measures (IM) that strongly affect their response is presented. A better understanding of the ground motion characteristics that affect the complex rocking response can lead the researchers to the appropriate seismic retrofitting technique. In order to specify the effect of ground motion characteristics on the seismic response of monument structures a large number of univariable and bivariable intensity measures are considered. Concluding to the most efficient intensity measures result in reduced uncertainties in the seismic demand model which could predict the rocking response with considerable accuracy. Hence leading to the construction of superior fragility curves.In the second section three novel spectral ground motion intensity measures are presented. The proposed intensity measures are calculated throughout the rocking rotational and the angular velocity spectra which are illustrated as 3D surface graphs with the slenderness α and the period parameter T, on the two horizontal axes. Thus the IMs are defined as the volume under the spectra calculated through integration. Intensity measures that quantify the information that the shape of the spectra provides and therefore enclose the structural response information of the majority of slender rocking blocks are intended to have a strong correlation with the rocking seismic response. The evaluation of the proposed intensity measures was made by examining well known from the literature characteristics such as efficiency proficiency and sufficiency.Assuming the fact that the monuments must remain intactmorphologically any proposed intervention method should not violate their form. Base isolation seems to be the only seismic protection method that fulfills those crucial criteria.In the third and final section the implementation of base isolation as a technique of protecting monumental structures is studied. Double friction pendulum (DFP) and triple friction pendulum (TFP) bearings are examined. In order to estimate the effectiveness of the base isolation on the seismic mitigation the alteration of the characteristics of the seismic signal which is propagated via the bearings is examined. Finally the observations obtained from the above procedure are corroborated by conducting dynamic analyses of an ancient rocking column standing free on an isolated base.

Degree

thesis:*
Grantor dc:publisher
Democritus University of Thrace (DUTH)
Year dc:date
2017

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Kavvadias, Ioannis
  • Καββαδίας, Ιωάννης

Subjects

dc:subject × 16

Rights

dc:rights
Statement dc:rights
  • BY_NC_ND
Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/41761

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Kavvadias, Ioannis; Καββαδίας, Ιωάννης. Διερεύνηση της δυναμικής απόκρισης ιστορικών μνημείων λικνιζόμενων υπό σεισμική διέγερση και της συνεισφοράς εφεδράνων τριβής πολλαπλής καμπυλότητας στη σεισμική τους θωράκιση. Democritus University of Thrace (DUTH), 2017. http://hdl.handle.net/10442/hedi/41761