Abstract
dc:descriptionIn the present thesis the seismic response of rigid rocking structural systems is investigated. Specifically the response of monumental structures is examined in this study. These structures such as free – standing columns colonnades and masonry arches consist representatives of rigid rocking SDOF oscillators.The original scientific contribution of the present thesis is categorized into three individual sections. In the first section a methodology that assesses the seismic vulnerability of the examined rocking systems based on the selection of the ground intensity measures (IM) that strongly affect their response is presented. A better understanding of the ground motion characteristics that affect the complex rocking response can lead the researchers to the appropriate seismic retrofitting technique. In order to specify the effect of ground motion characteristics on the seismic response of monument structures a large number of univariable and bivariable intensity measures are considered. Concluding to the most efficient intensity measures result in reduced uncertainties in the seismic demand model which could predict the rocking response with considerable accuracy. Hence leading to the construction of superior fragility curves.In the second section three novel spectral ground motion intensity measures are presented. The proposed intensity measures are calculated throughout the rocking rotational and the angular velocity spectra which are illustrated as 3D surface graphs with the slenderness α and the period parameter T, on the two horizontal axes. Thus the IMs are defined as the volume under the spectra calculated through integration. Intensity measures that quantify the information that the shape of the spectra provides and therefore enclose the structural response information of the majority of slender rocking blocks are intended to have a strong correlation with the rocking seismic response. The evaluation of the proposed intensity measures was made by examining well known from the literature characteristics such as efficiency proficiency and sufficiency.Assuming the fact that the monuments must remain intactmorphologically any proposed intervention method should not violate their form. Base isolation seems to be the only seismic protection method that fulfills those crucial criteria.In the third and final section the implementation of base isolation as a technique of protecting monumental structures is studied. Double friction pendulum (DFP) and triple friction pendulum (TFP) bearings are examined. In order to estimate the effectiveness of the base isolation on the seismic mitigation the alteration of the characteristics of the seismic signal which is propagated via the bearings is examined. Finally the observations obtained from the above procedure are corroborated by conducting dynamic analyses of an ancient rocking column standing free on an isolated base.
Degree
thesis:*- Grantor dc:publisher
- Democritus University of Thrace (DUTH)
- Year dc:date
- 2017
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Kavvadias, Ioannis
- Καββαδίας, Ιωάννης
Subjects
dc:subject × 16- Λικνισμός
- Σεισμική μόνωση βάσης
- Εφέδρανα ολίσθησης
- Σεισμικές παράμετροι
- Σεισμική τρωτότητα
- Αρχαίοι κίονες
- Rocking response
- Base isolation
- Friction pendulum bearings
- Ground motion intensity measures
- Seismic fragility
- Ancient columns
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Πολιτικού Μηχανικού
- Engineering and Technology
- Civil Engineering
Rights
dc:rights- Statement dc:rights
-
- BY_NC_ND
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/41761