University of Patras
Πειραματική διερεύνηση σταδιακής κατάρρευσης κτιρίων οπλισμένου σκυροδέματος λόγω τυχηματικών δράσεων
Abstract
dc:descriptionDespite the fact that extreme actions on structures, such as explosions or impacts, have low probability of occurrence, their consequences could lead to structural failure and collapse; local damage to one member may spread successively to the others. The present thesis investigates experimentally the loss of a vertical support in both planar and three-dimensional reinforced concrete (RC) structures. The research interest was focused not only on the case of an accidental loss leading structures to progressive collapse, but also on possible ways to enhance their response to avoid collapse. At first, the effects of accidental loss of a column on the beams connected to it and the slab they support were examined. Two specimens, which were models of subassemblies of the prototype building, were used to investigate the load redistribution. The results were combined and showed a significant margin of the bearing capacity of the beams-slab system; the slab contributed significantly when the beams reached their capacity. In a second set of tests, the specimens had exactly the same geometry as in the former tests, but the beams were constructed alternatively (dry joints and axial prestressing of beams) and the slabs’ reinforcement configuration was different (continuous reinforcing bars at the top and bottom flange) – these characteristics have been proven to enhance the resilience and robustness of structures for seismic actions; it was found that the response of both beams and slabs in terms of the load bearing capacity margin was considerably enhanced. Field evidence shows that the effects of major damage to columns by seismic action may not lead to collapse of the structure if the top floor is infilled. Therefore, the contribution of infilled frames to the response of RC structures in the case of accidental loss of a column was studied: tests were conducted, removing instantly ground story columns (one at a time) of a two-story RC structure whose top story perimeter frames were infilled; the distribution and configuration of infills were indicative of real-life structures (i.e. non-infilled frames, fully infilled frames, or infilled frames with openings). The tests showed that the contribution of the infills to the resilience of the structure against progressive collapse is significant, leading to lower deformations of the beams at the position of the loss of the vertical support and in general to lower deformations of the bays and the members affected by the incident, compared to non-infilled bays of the structure.Structures can be protected from seismic damage and residual deformation if they rock as a whole relative to the shaking ground, or if their components rock in a stable way with respect to each other as rigid bodies. Building on the positive results of the seismic resistant beam specimens in the case of loss of support, a RC frame was tested in lateral loading, constructed in a similar way to the beam specimens: dry joints, unbonded post-tensioned cables continuous and concentric along all beam spans. Moreover, the footings of the columns were free to rock and uplift. The rocking frame performed much better and showed significantly less damage compared to the fixed-base frame (also investigated experimentally); the latter suffered severe damage at the beams and columns. The present thesis is structured in five chapters. In Chapter 1, the main research question and the way it has been addressed in several design codes is presented, along with the thesis’ main objectives. The response of beams and slabs of a six-story RC structure affected by the accidental loss of a vertical support is studied in Chapter 2. Tests are conducted on specimens of beams and slabs at a scale of 0.6:1 and 1:1.5, respectively. Chapter 3 examines the contribution of masonry infills to structures against progressive collapse due to loss of a support, by testing a two-story RC building in a column loss scenario at a scale of 1:1.25. The seismic response of a two-story RC precast frame, at a scale of 0.6:1, with its footings free to rock and uplift, is studied in Chapter 4. Finally, in Chapter 5 the summary and the conclusions drawn are presented.
Degree
thesis:*- Grantor dc:publisher
- University of Patras
- Year dc:date
- 2017
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Stathas, Nikolaos
- Σταθάς, Νικόλαος
Subjects
dc:subject × 20- Κατασκευές οπλισμένου σκυροδέματος
- Ακραίες δράσεις
- Απώλεια στήριξης
- Προοδευτική κατάρρευση
- Ανθεκτικότητα κατασκευών
- Πειραματικές δοκιμές
- Κατασκευές ΟΣ με ξηρές συνδέσεις
- Μη-φέρουσες τοιχοπληρώσεις
- Reinforced concrete structures
- Extreme actions
- Support loss
- Progressive collapse
- Structures resilience
- Experimental tests
- Dry-jointed RC structures
- Masonry infills
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Πολιτικού Μηχανικού
- Engineering and Technology
- Civil Engineering
Rights
dc:rights- Statement dc:rights
-
- BY
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/42083