National Technical University of Athens (NTUA)
Βελτιστοποιημένες διατάξεις σύζευξης σε συχνότητες THz
Abstract
dc:descriptionIn the present dissertation, a new approach for efficient detection of THz radiation in biomedical imaging applications is proposed. Various absorption elements were designed, simulated and constructed to improve the detection characteristics of a microbolometer. Moreover, experimental measurements were carried out in both polymeric and pharmaceutical materials to study their THz radiation characteristics. Initially, a double-layered absorber consisting of a 32 nm thick aluminum (Al) metallic layer, placed on a glass medium (SiO2) of 1 mm thickness, was fabricated and used to design a fine-tuned absorber through a theoretical and finite element modeling process. The absorption of the fine-tuned structure was calculated both analytically and by finite element modeling resulting in satisfactory agreement. Finite element modeling provides a convenient way to extract the amount of power dissipation in each layer and is used to quantify the THz absorption in the double-layered structure. The results indicate that the proposed low-cost, double-layered absorber can be tuned based on the metal layer sheet resistance and the thickness of various glass media. This can be done in a way that takes advantage of the diversity of the absorption of the metal films in the desired THz domain (6 to 10 THz). It was found that the composite absorber could absorb up to 86% (a percentage exceeding the 50%, previously shown to be the highest achievable when using single thin metal layer) and reflect less than 1% of the incident THz power. This approach will enable monitoring of the transmission coefficient (THz transmission ‘’fingerprint’’) of the bio sample with high accuracy, while also making the proposed double-layered absorber a good candidate for a microbolometer pixel’s active element.Based on the aforementioned results, a more sophisticated and effective double-layered absorber was developed. The glass medium has been substituted by diluted poly-si and the results were twofold: An absorption factor of 96% was reached and high TCR properties acquired. In addition, a generalization of these results and properties over the active frequency spectrum was achieved. Specifically, through the development of a theoretical spectral linear equation having as input any arbitrary frequency in the IR spectrum (0.3 to 405.4 THz) and as output the appropriate thickness of the poly-si medium, the double-layered absorber retains the ability to absorb the 96% and reflects less than 1% of the incident power. As a result, through that post-optimization process and the spread spectrum frequency adjustment, the microbolometer detector efficiency has been further improved. Finally, taking into account the cutting-edge technology in microbolometric devices, the advantages of the developed absorption element of the present dissertation were identified and highlighted.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2017
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Bolakis, Christos
- Μπολάκης, Χρήστος
Subjects
dc:subject × 12- Τερακυματική ακτινοβολία
- Βιοϊατρικές εφαρμογές
- Βελτιστοποίηση απορρόφησης
- Υβριδική φύση
- Terahertz radiation
- Biomedical applications
- Absorption optimization
- Hybrid nature
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ
- Engineering and Technology
- Electrical Engineering, Electronic Engineering, Information Engineering
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/42232