Ανάπτυξη και εφαρμογή τεχνικών προσδιορισμού πολύ χαμηλών συγκεντρώσεων ραδιενεργών ιχνοστοιχείων σε δείγματα περιβαλλοντικής σημασίας
Abstract
dc:descriptionThe aim of this PhD Thesis was the determination of very low concentrations of natural and artificial radioactive isotopes in environmental samples by means of gamma-spectroscopy techniques. Natural and artificial radioactive isotopes of low or higher specific activity are contained and can be detected in any environmental sample. Even when their specific activity is low, leading to negligible radiobiological significance, their detection is of interest in various applications, such as their use as tracers for environmental processes. In addition, improving the levels of detection of an isotope using a γ-spectroscopic apparatus, may allow the detection of the isotope in smaller volume samples without significant compromise on the accuracy of the measurement, which has obvious consequences in the design of the sampling. Since the background of a γ-spectroscopic apparatus is a factor determining the ability to detect low levels of radioactivity in a sample, its reduction is always highly desirable.In the framework of the Thesis the installation, study and use of the new Compton Suppression system (CSS), which was installed on the XtRa detector of the N.E.D. - N.T.U.A was carried out, aiming the reduction the continuous background of the detector and the improvement of the detection limits of the XtRa - CSS apparatus. The electronic set-up of the apparatus allows for the simultaneous collection of two spectra with a suppressed or not (unsuppressed) continuous background. In the framework of the study, a series of response factors were used, as referred in literature, through which the effect of various phenomena observed in the detection of photons by the Compton Suppression system was identified, and should be taken into account both during the calibration of the device, and during routine analyzes. As a result of this study, the optimal conditions for the detection of each isotope are proposed. The device was then calibrated experimentally but also using Monte Carlo simulation techniques for a series of source-to-detector geometries. For this purpose, it was necessary to modify the PENELOPE simulation code used in the N.E.D. - N.T.U.A in order to take into account both the true coincidence phenomenon during spectrum collection and to simulate a Compton Suppression system consisting of two independent detectors (primary detector and secondary detector or active shield) that communicate with each other.One of the main objectives of the Thesis was the detection of radioactive isotopes found at very low concentrations in environmental samples. For this purpose appropriate sampling techniques for atmospheric aerosols and liquid atmospheric precipitations and sample preparation were developed and a large number of samples were analyzed, mainly (a) contaminated samples due to the nuclear accidents in Chernobyl and Fukushima, (b) atmospheric aerosol and precipitation samples. From these analyzes it was possible to detect 241Am from the Chernobyl accident and a strong correlation with the 137Cs concentration was found. In addition, the use of the Compton Suppression System allowed for the detection of artificial radioactive isotopes due to the Fukushima accident in atmospheric aerosol and precipitation samples, in concentration of the order of a few tens of mBq/m3, as well as the detection of natural radioactive isotopes of earth and cosmic origin such as 210Pb, 7Be and 22Na – which is extremely difficult to detect because of its very low radioactivity, of 1 μBq/m3 – isotopes that are used in the literature as tracers for atmospheric processes.At N.E.D. - N.T.U.A the technique of neutron activation for the detection and quantification of a series of non-radioactive trace elements has been applied for many years. The XtRa - CSS apparatus was also used to detect more elements and to improve the detection limits of the method. In the framework of the Thesis, a series of irradiation-γ-spectroscopic analysis scenarios were examined, which, combined to the use of the XtRa - CSS apparatus, allowed for the detection of 15 elements and trace elements (Al, As, Au, Cu, Eu, Fe , Ga, K, La, Mg, Mn, Na, Sb, Sc, Zn) and improved the lower limits of detection up to 7 times compared to the past. In addition, the appropriate calibration coefficients were determined to allow the quantification of the above elements in environmental samples such as soil, fly ash, marine sediment and industrial slag.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2017
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Savva, Marilia
- Σάββα, Μαρίλια
Subjects
dc:subject × 8Rights
dc:rights- Statement dc:rights
-
- BY_NC_SA
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/42279