Back to search

Aristotle University Of Thessaloniki (AUTH)

Επεξεργασία υδάτων με συνδυασμό οζονισμού και μεμβρανών

Abstract

dc:description

The aim of the present thesis is to investigate the feasibility of applying a gas-liquid membrane contactor for ozone and peroxone treatment of surface water. α-Al2O3 (ceramic) membranes were selected for the development of the respective ozone contactor, due to their high chemical and mechanical stability, as well as their sufficient porosity structure. Initially, the influence of hydrophilic/hydrophobic character of the membrane contactor on the efficiency of ozone transfer to water was evaluated. For this purpose, the internal surface of the tubular α-Al2O3 membranes was chemically modified with four different organosilanes, in order to increase their hydrophobic behavior. Bubble point calculations confirmed the benefits of using hydrophobic membranes for ozone transfer to water. The increase of α-Al2O3 hydrophobicity reduced the required pressure difference to displace the aqueous phase from the membrane pores, thus allowing the gas-liquid interface to be defined on its inner surface. α-Al2O3 membrane modified with trichloromethylsilane (triClMS) showed the highest hydrophobicity (contact angle 140°) and hence, was selected for the development of ozone contactor. The chemically modified “triClMS” membrane was subsequently used to study the transfer of ozone to water only through diffusion phenomena. The influence of major parameters (i.e. pH value, temperature etc.) on dissolved ozone concentrations, measured at the outlet of the membrane module, was also investigated. A mathematical model considering all the simultaneously occurring phenomena during ozone transfer was also developed. The model was able to describe/predict with good agreement with the experimental results, the dissolved ozone concentrations at the outlet of contactor module. The presented model permits also the further exploitation-extrapolation of data for different devices and experimental conditions. The impact of O3 or O3/H2O2 treatment via the membrane contacting system on the composition and characteristics of natural organic matter (NOM) was also studied. The experiments were performed using natural waters collected from Aliakmonas and Axios Rivers. UV absorbance at 254 nm, DOC concentration, specific UV absorbance, fluorescence spectroscopy and LC-OCD measurements were performed in order to evaluate the changes of NOM. Conventional batch O3 and O3/H2O2 experiments were conducted to investigate the effect of different contacting patterns. The results revealed that the different reaction pathways followed during membrane contactor and conventional batch experiments may also influence the formation of NOM oxidation intermediates. Finally, the performance of the membrane contacting process for ozone and peroxone treatment of surface water contaminated with various organic micropollutants was investigated. Carbamazepine, benzotriazole, p-chlorobenzoic and atrazine degradation, as well as bromate formation, were evaluated as typical model compounds to study the efficiency of ozone transferred through the hydrophobized ceramic membrane.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2017

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Stylianou, Stylianos
  • Στυλιανού, Στυλιανός

Subjects

dc:subject × 16

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/42730

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Stylianou, Stylianos; Στυλιανού, Στυλιανός. Επεξεργασία υδάτων με συνδυασμό οζονισμού και μεμβρανών. Aristotle University Of Thessaloniki (AUTH), 2017. http://hdl.handle.net/10442/hedi/42730