Back to search

National and Kapodistrian University of Athens

Χρήση επαναληπτικού αλγορίθμου ανακατασκευής εικόνας σε αξονικές τομογραφίες θώρακος υψηλής ευκρίνειας σε παιδιά: διερεύνηση της ποιότητας της εικόνας σε σχέση με τη δόση της ακτινοβολίας στον εξεταζόμενο

Abstract

dc:description

Purpose of the study: High radiosensitivity of children undergoing computerized tomography (CT) has rendered the use of the recently developed Iterative Reconstruction (IR) Algorithms particularly significant. This study compares the iDose4 IR Algorithm with Filtered-Back Projection (FBP) in terms of radiation exposure and image quality (IQ) in 77 chest high resolution CT (HRCT) examinations performed in children with chronic suppurative lung disease at our Department during the years 2011 – 2017.Materials and Methods: Twenty seven patients were scanned using the FBP protocol (FBP group) while 50 patients using the iDose4 protocol (iDose group) and reduced tube current-time product (mAs), both on a 64-detector row CT scanner. The iDose group images were reconstructed with all iDose levels (1 to 7). Radiation exposure quantities were estimated, while subjective and objective IQ were evaluated. Unpaired t-tests were used for data statistical analysis. All results were compared on the basis of weight category (more or less than 30kg).Results: The iDose application allowed a statistically significant effective dose reduction both for children <30kg (78.1%, p<0.001) and children >30kg (54.3%, p=0.001). Subjective overall IQ evaluation was comparable between the 2 groups of patients with iDose level 5 in the >30kg subgroup and with iDose level 6 in the <30kg subgroup, whereas objective image noise was comparable between FBP and iDose level 6 images in the <30kg subgroup and between FBP and iDose level 1 images in the >30kg subgroup of paediatric patients.Conclusions: The use of the iDose4 IR algorithm in pediatric chest HRCT leads to significant dose reduction without compromising IQ and it could be established in the future as the low-dose gold standard imaging examination for children with clinical indication of chronic suppurative lung disease.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2018

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Smarda, Magdalini
  • Σμαρδά, Μαγδαληνή

Subjects

dc:subject × 12

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/42894

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Smarda, Magdalini; Σμαρδά, Μαγδαληνή. Χρήση επαναληπτικού αλγορίθμου ανακατασκευής εικόνας σε αξονικές τομογραφίες θώρακος υψηλής ευκρίνειας σε παιδιά: διερεύνηση της ποιότητας της εικόνας σε σχέση με τη δόση της ακτινοβολίας στον εξεταζόμενο. National and Kapodistrian University of Athens, 2018. http://hdl.handle.net/10442/hedi/42894