Συγκριτική μελέτη θερμομέτρησης νεογνών με υδραργυρικό θερμόμετρο και με θερμόμετρα νέων τύπων
Abstract
dc:descriptionIntroduction: Monitoring temperature fluctuations in neonates can preventmorbidity caused by high or very low body temperature and should be donewith a reliable thermometer device.Aim: The aim of this study was to investigate correlations betweenmeasurements taken with four different thermometer devices in four differentneonatal temperature sites.Material and Methods: The study sample included 400 term neonates withgestational age 37–42 weeks. The temperature measurements wereperformed using mercury-in-glass thermometer, a digital thermometer, atympanic thermometer and an infrared forehead thermometer. Paired t test,Interclass Correlation Coefficient (ICC) and the Bland-Altman plot were usedto compute data.Thermometers used for this study were a mercury-in-glass thermometer, aninfrared tympanic thermometer (BRAUN® Thermo scan ear thermometermodel IRT 4520), a digital thermometer (Kendall, Filac™ 3000 EZ) and adigital forehead thermometer (Visiomed Thermoflash LX-26). Thetemperature measurements were taken consecutively starting with theforehead site, then tympanic, axilla and last rectum from the same person, who was trained to do the measurements. Prior to the study, three mercury-in glass thermometers were standardized in a water bath (set at 37 0C). All themercury-in-glass thermometers were shaken to decrease the reading to 35°Cbefore each temperature measurement.Results: The mean gestational age of the neonates who participated in thisstudy was 38.9 ± 1.2 weeks. Of the 400 neonates, 202 (50.5%) were femalewhile 198 (49.5%) were male with a female/male ratio of 1.02:1. The meanage at the time of recruitment was 2.5± 0.8 days. Analyzing the data, therewas a significant positive correlation between rectal mercury-in-glass anddigital thermometer temperatures. The interclass correlation coefficient (ICC)was 0.93 (95% CI = 0.92 to 0.94, p<0,001) which indicates very closeagreement.Also, when the rectal mercury-in-glass and tympanic measurements werecompared, the ICC was 0.64 (95% CI = 0.58 to 0.69, p <0.001) whichindicates close agreement. However, when the rectal mercury-in-glassmeasurements and forehead measurements were compared, the ICC was0.28 (95% CI = 0.18 to 0.36, p <0.001) suggesting little agreement betweenthem.Finally, comparing the axillary mercury-in-glass and digital thermometermeasurements, the ICC was 0.9 (95% CI 0.88 to 0.92, p <0,001) which indicates very close agreement among them.Conclusion: The optimal way to measure body temperature in neonates isrectally with a mercury-in-glass or digital thermometer. Reliable seem to bethe axillary measurements using a mercury-in-glass or digital thermometerand to a lesser degree the tympanic measurements. Finally, measuringneonates’ temperature with a forehead thermometer seems to be unreliable.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2015
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Kotsia, Efygenia
- Κώτσια, Εφυγένια
Subjects
dc:subject × 14Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/42990