Σύγκριση διοισοφαγείου και διακρανιακού υπερηχογραφήματος στη διάγνωση του ανοιχτού ωοειδούς τρήματος σε ασθενείς υπό μηχανικό αερισμό

Abstract

dc:description

Patent foramen ovale (PFO) is an anatomic variant that may lead to several pathological conditions, notably right to left shunt and hypoxemia in mechanical positive pressure determining ventilated patients. For this reason, awareness of its existence might be important in the best ventilator settings and managing severely hypoxemic patients. Contrast-enhanced transesophageal echocardiogram (TEE) is a semi-invasive test that is generally considered to be the gold standard for PFO detection. In the present study we hypothesized that, in the above population, the transcranial Doppler ultrasonography (TCD) is another valuable, albeit simpler, non-invasive test for the detection of a PFO that causes a right-to-left shunt; and its performance in this diagnosis has not been validated in this population. Hence, the aim of this study has been to determine the occurrence of a PFO causing right-to-left shunt and estimate the accuracy of the TCD in its detection, using the TEE as the reference method of the diagnosis, in mechanically ventilated ICU patients, under different settings; and further our understanding about respiratory and hemodynamic parameters potentially associated with an open foramen ovale detection.In addition in order to determine the respiratory and hemodynamic factors that may lead to FO opening, we study the effect of that certain indicators in detecting a PFO or in opening of the Foramen Ovale.Methodology: In this prospective observational study we recruited 107 consecutive mechanically ventilated ICU patients who had another indication to undergo a TEE. Each patient was tested for a PFO using both a (contrast-enhanced) TEE and a TCD. At least three bubble tests were performed in order to assess for an open PFO, by administering 10ml of stirred Haemaccel ®, 5 minutes apart from each other. In each patient, the right ventricle (RV) end-diastolic area, left ventricle (LV) end-diastolic area, and the LV ejection fraction (by the Simpson’s method) were measured at the mid-esophageal four-chamber view. Ventilatory parameters such as tidal volume, plateau pressure during inspiration (p-plateau), static lung compliance, and positive end-expiratory pressure were recorded as well. Based on our findings, we assessed the sensitivity, specificity, the positive and the negative predictive values of the TCD in the detection of a PFO causing right-to-left shunt. Subsequently, we examined the validity of these attributes of the TCD in different patient subpopulations, which were defined based on differences in the level of their total positive end-expiratory pressure (PEEP) value (i.e., higher and lower than 8 cmH2O); their p.plateau value (i.e., higher and lower than 26 cmH2O); the dimensions of right ventricle (i.e., higher and lower than dimensions of the Left ventricle ); and the presence or absence of ARDS. In relation to that, we noted the frequency of a PFO detection under these conditions in which the PEEP, p.plateau value, RV dimensions and lung compliance differed. Results: The prevalence of a PFO in the above patient sample was found to be 27%. The sensitivity of the TCD test in detecting a PFO that causes right-to-left shunt in the entire population of the study was 97%; while the specificity was 70%.The latter was slightly higher in patients on a high PEEP value, i.e., 83%. Both the sensitivity and the specificity were higher in the ARDS subgroup, i.e., 100% and 86%, respectively. An association was noticed between a PFO detection and a p.plateau>26cmH2O (odds ratio 3.4, 95 % CI: 1.2–-9.4, p =0.017) . Profound right ventricular dilatation (RV>LV area) was also associated with more frequent PFO detection (odds ratio 3.1, 95 % CI: 1.2–-8.075, p =0.018).Conclusion: The prevalence of a PFO in the mechanically ventilated patients is high, and appears to be similar to the one in the general population. The sensitivity of the TCD in detecting a PFO is high, hence a TCD may safely rule out the existence of a PFO when the test result is negative. Due to its simplicity and non-invasive nature, the TCD may need to be considered as a screening test to be performed first, in cases in which a TEE is not required for another reason. However the accuracy of TCD in diagnosing the presence of a PFO is limited, even though it appears slightly improved when the PEEP value is high and or the patient has an ARDS; and requires verification with a TEE. In the latter case, the combination of the two tests potentially improves the likelihood of a PFO detection. Moreover it is possible that, high pressure in the right chambers, plays a role in foramen ovale opening but further studies are required to verify this concept.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2018

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Vavlitou, Anna
  • Βαβλίτου, Άννα

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • BY
Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/43043

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Vavlitou, Anna; Βαβλίτου, Άννα. Σύγκριση διοισοφαγείου και διακρανιακού υπερηχογραφήματος στη διάγνωση του ανοιχτού ωοειδούς τρήματος σε ασθενείς υπό μηχανικό αερισμό. Aristotle University Of Thessaloniki (AUTH), 2018. http://hdl.handle.net/10442/hedi/43043