Democritus University of Thrace (DUTH)
Η μελέτη μιας νέας τροποποιημένης τεχνικής για διαδερμική μονόπλευρη διαυχενική κυφοπλαστική των θωρακικών σπονδύλων με ειδικά σχεδιασμένα εργαλεία: εργαστηριακή και πτωματική μελέτη
Abstract
dc:descriptionVertebroplasty and kyphoplasty are the two methods of choice for the treatment of compressive vertebral fractures, particularly thoracic spine. Vertebroplasty is an accepted method for treating compressive spine fractures.This method does not correct the compressive deformation of the vertebral body as opposed to the ciphoplasty but "freezes" the already existing deformation, with the result that the injection of cement requires more pressure/force to pass through the needle through which it is injected acrylic cement in the body of the vertebra. This often causes leakage of acrylic cement outside the vertebra wall in relation to what is observed in the kyphoplasty.Complicated fractures are now being treated internationally by the method of kyphoplasty. The morphology of the vertebrae of the middle and upper thoracic spine (T1-T5) makes it difficult to place the trocar through the pedicle. The dimensions of the pedicle and its direction in relation to the sagittal and axial plane, combined with possible deformations of the Thoracic spine as in the case of kyphosis, further alter their anatomical characteristics, making it more difficult for the transpedicular approach. Additional difficulties arise due to the shoulder joint interference during fluoroscopy for lateral imaging of the upper and middle vertebral bodies during surgery.Kyphoplasty is the method that relieves the patient from the pain caused by the fracture, giving him the quality of life immediately after surgery and the opportunity to avoid further taking analgesic medication.The purpose of this novel study was to investigate the feasibility of unilateral transpedicular balloon kyphoplasty particularly of the upper thoracic vertebrae using an 11- gauge balloon and cement inserter, and to study the morphological parameters of the thoracic spine pedicles. We used four fresh frozen cadaveric thoracic spines with intact rib cages and skin for kyphoplasty from T1 to T12 vertebrae under C-arm uoroscopy. The most limiting width of the pedicles 2.46+/-0.32mm was in the middle levels (T5-T8). The absolute minimum height of the pedicles was at T1 (3.80-3.87mm). All regions of the vertebral body were effectively targeted for cement augmentation. The average cement load of all the vertebral bodies was 43,22%. Using the kyphoplasty technique in combination with the pre-bent 11mm memory-alloy cement inserter allowed targeting of the desired position of the vertebral body for effective vertebral body cement augmentation.
Degree
thesis:*- Grantor dc:publisher
- Democritus University of Thrace (DUTH)
- Year dc:date
- 2018
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Vastardis, Georgios
- Βασταρδής, Γεώργιος
Subjects
dc:subject × 6Rights
dc:rights- Statement dc:rights
-
- BY_NC_ND
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/43253