dc:description

Aim: The aim of the present study was to investigate the hearing damagecaused by firearms, as well as to evaluate the effectiveness of existing hearingprotection devices. Furthermore, our main aim was to explore the possible utilityof otoacoustic emissions (OAEs) and efferent system strength in order todetermine vulnerability to noise exposure in a clinical setting and foresee animpending hearing handicap.Material/Method: The study group of our cohort comprised of 344 volunteerswho had just begun mandatory basic training as Hellenic Corps Officers MilitaryAcademy cadets. Pure-tone audiograms were obtained at frequencies 0.25,0.5, 1, 2, 3, 4, 6 and 8 kHz on both ears. Furthermore participants weresubjected to diagnostic transient evoked otoacoustic emissions (TEOAEs)using ILO 292 DP Echoport instrument. Finally, they were all tested for efferentfunction through suppression of TEOAE’s with contralateral noise. Followingbaseline evaluation, all cadets fired ten rounds using a 7.62mm Heckler & KochG3A3 assault rifle while lying down in prone position. Immediately afterexposure to gunfire noise and no later than 10 hours, all participants completedan identical protocol for a second time, which was then repeated a third time,30 days later.Results: The data showed that after the firing drill 280 participants suffered atemporary threshold shift (TTS) (468 ears), while in the third evaluationconducted 30 days after exposure 142 of these ears still presented a thresholdshift compared to the base line evaluation (Permanent threshold shift - PTSears). In 454 of the ears, showing a temporary threshold shift (TTS), partial ortotal recovery of the threshold occurred (ie either did not show a (PTS) (326ears), or exhibited a PTS, but this was quantitatively less than the (TTS) (128ears)). It was also found that as the range of TTS increased, the possibility ofPTS also increased. However, especially as far as PTS was concerned, thefinal hearing threshold exceeded 20 dB HL (normal hearing threshold), in asmuch as four ears (1.7%). Concerning the frequency range of the hearingdamage, no TTS or PTS occurred at 250, 500 and 1000 Hz frequencies. Threshold shifts mostly occurred at 3 kHz (343 ears with TTS (49.9%) and 62ears with PTS (9.1%).There was no statistical correlation between loss of OAEs amplitudebetween first and second evaluation and TTS (p = 0.092), while a statisticalcorrelation was found between loss of OAEs amplitude between the first andthe third evaluation and PTS (p <0.001). Finally, all efforts to establish aquantitative correlation between OAEs amplitude and audiometric thresholdshifts did not yield statistically significant results.As far as efferent function was concerned, mean suppression of OAE’samplitude was 1.494 dB SPL with a SD of 0.95.A Receiver operating characteristics (ROC) curve analysis showed thatOAE’s amplitude is predictive of future TTS and PTS. The area under the curve(AUC) for TTS was 0.582 (95% CI: 0.517-0.648; P=0.017) and 0.745 for PTS(95% CI: 0.680-0.809; P<0.001). The results were slightly different forsuppression of OAE’s (TTS AUC 0.548 (95% CI: 0.480-0.615; P=0.167) andPTS AUC 0.566 (95% CI: 0.492-0.640; P=0.077)) showing only a slight trendtowards significance. The curves were used to determine cut points to evaluatethe likelihood of TTS for OAE’s amplitude in the baseline evaluation. Decisionlimits yielding 71.6% sensitivity are 12.45 (positive if less than or equal to thisvalue) with 63.8% specificity for PTS, and 50% sensitivity are 12.35 (positive ifless than or equal to this value) with 68.2% specificity for TTS.Conclusions: Noise induced hearing loss remains a significant problem amongmilitary personnel, despite adoption of hearing protective devices. Thus theneed for careful and thorough monitoring of such populations and combinationof protective measures, eg simultaneous use of both earplugs and ear muffs, isof crucial importance. However, it is noteworthy that the recorded damageshardly led to any actually significant hearing handicap (audiometric thresholdover 20 dB HL), at least due to only a single exposure to gunfire noise. Therange of temporary hearing loss (TTS) was found to correlate with whether apermanent threshold shift (PTS) would occur. The 3 kHz frequency should be included in a routinely manner in the audiometric evaluation of populationsexposed to noise.In addition, it was confirmed that establishing a "virtual audiogram”,through OAEs, is not possible, as there is a weak and unstable correlationbetween the amplitude of OAEs and audiometric threshold shifts. Regardless,the significance and usefulness of OAEs in monitoring populations exposed tonoise, complementary to audiometry, was also confirmed.Interestingly our data yielded tentative evidence to suggest that OAE’samplitude is both sensitive and specific enough to efficiently identify subjectsthat are particularly susceptible to hearing loss caused by impulse noisegenerated by firearms. Hearing conservation programs may therefore want toconsider including them in their routine in order to take preemptive steps toprevent such damages from occurring. As far as efferent strength is concerned,we feel that further research is due, before implementing suppression of OAE’sin hearing conservations programs in a similar manner.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2018

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Blioskas, Sarantis
  • Μπλιόσκας, Σαράντης

Subjects

dc:subject × 12

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/43340

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Blioskas, Sarantis; Μπλιόσκας, Σαράντης. Μελέτη της επίδρασης του θορύβου στην ακοή, σε συνάρτηση με τη λειτουργία της ελαιοκοχλιακής δεσμίδας και τη χρήση ωτοακουστικών εκπομπών. Aristotle University Of Thessaloniki (AUTH), 2018. http://hdl.handle.net/10442/hedi/43340