Back to search

University of Ioannina

Numerical, simulations of blood flow effects under the presence of abdominal aortic aneurysm

Abstract

dc:description

Abdominal aortic aneurysms (AAAs) are defined as a localized dilatation of the abdominalaorta featuring diameter at least 50% larger than the normal one. AAAs usually remainasymptomatic until the occurrence of a possibly catastrophic complication, i.e. the rupture.Endovascular aneurysm repair (EVAR) offers a reliable treatment for the disease by excludingthe aneurysmal sac and redirecting blood flow through an endovascularly deployed stent-graftsystem.Computational fluid dynamics (CFD) is a scientific field involved actively in the study ofblood flow throughout the circulatory system. The numerical simulations of blood flow have attracted the interest of the medical community due to their non-invasive character, relativelylow resource demands (compared to experiments), their flexibility and the quantity of highresolutionflow analytics that are capable of providing. Recent technological advancementshave enabled the combination of CFD with medical imaging data, extending the applicabilityof CFD to patient-specific vascular models. Researchers are using CFD to unravel possibleimplications of hemodynamic flow in the pathogenesis, evolvement and rupture of AAAs. Theapplications of CFD are not limited to physiological or pathological blood flow but can beemployed in the context of EVAR as well.The aim of the current thesis was to explore the capabilities of numerical simulations andset up applications in physiological, preoperative and postoperative AAA cases. Chapter 1introduces an alternative modeling of intraluminal thrombus (ILT) which is apparent in mostAAAs and has a crucial role in their growth. Specifically, ILT is modeled as a porous mediumwith gradually smaller permeability following histological analyses of evolving ILT structures.The differential equations that describe the interaction of pathological blood flow with agrowing ILT are discretized with the Finite Element method and solved by an in-housenumerical code in an AAA model. The analysis gives an estimate of the ILT effects on the flowconditions in AAAs that is in agreement with the biomechanical factors that according to theliterature promote ILT initiation and growth.The literature states that the percentage of post-EVAR complications is variable among thecommercial endografts. However there are only a few clinical, computational or experimentalstudies, providing hemodynamic data in an endograft-specific manner. Additionally, it isknown that the implantation of an endograft alters hemodynamics with possible adverse effectson the functionality of the device itself, but there is not a consistent methodology to calculatethe blood flow variations specifically. Chapters 2,3 and 4 are attempting to answer openquestions regarding the hemodynamic efficiency of EVAR and unravel the hemodynamicprofile of various commercial endografts using advanced dynamic three-dimensionalnumerical simulations coupled with patient-specific medical data. The methodology involves:1) the collection of suitable medical cases, 2) reconstruction of computed tomography data toacquire the geometrical representation of patient-specific AAAs or endograft structures, 3)generation of numerical grids to enable capturing high-resolution hemodynamic analytics, 4)performance of numerical simulations using CFD, 5) post-processing of the results focusingon regions of interest within the models, 6) visualization of hemodynamic properties andpatterns and 7) statistical analysis to determine the significance of the flow variations.

Degree

thesis:*
Grantor dc:publisher
University of Ioannina
Year dc:date
2016

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Raptis, Anastasios
  • Ράπτης, Αναστάσιος

Subjects

dc:subject × 30

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/43374

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Raptis, Anastasios; Ράπτης, Αναστάσιος. Numerical, simulations of blood flow effects under the presence of abdominal aortic aneurysm. University of Ioannina, 2016. http://hdl.handle.net/10442/hedi/43374